MODEL | Unit | MD60D | |
Rated-heating-capacity | KW | 24.5 | |
Hot-water-supply | L/h | 520 | |
Average-heating-input-power | KW | 5.68 | |
Rated-heating-input-current | A- | 27/12 | |
Max-outlet-water-temp | °C | 60 | |
COP | - | 4.2 | |
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing-size | W*D*H | mm | 1200*520*1350 |
Unit-weight | KG | 240 | |
Refrigerant | - | R417A/R407C | |
Working-air-temp-range | - | (-15°C)—45°C | |
compressor | Type | - | Copeland |
Air-source-heat-exchanger | Type | - | Finned-heat-exchange |
Fan-Type | - | axial-flow-fan | |
Hot-water-side-heat-exchange | Type | - | Coil-heat-exchanger |
Water-flow | L/H | 6000L/h | |
Water-pressure-down | Kpa | 48 | |
Pipe-size | DN | 40 |
-
Spare-part-instruction-:
1.-using-larger-evaperator-,specially-made-for-cold-weather-place.
-
2.-condenser-use-internal-and-external-thread-sleeve-type-heat-exchanger-,-have-high-heat-exchanger-effciency-and-large-internal-diameter-so-that-prevent-water-blocking-because-of-dirty-,make-more-space-to-get-heat-exchanger
-
3.use-scroll-compressor,-working-stable-and-long-lifetime.
-
4.-centrifugal-fan-motor-make-sure-low-noise-and-beautiful-outlooking.
-
5.-use-electric-expansion-valve,-adjust-the-refrigerant-flow-automatically.
-
6.-adopt-PID-defrosting,-defrost-according-to-time,-evaperate-temperature-and-environment-temperature.
7.Touch-screen-design,-and-LCD-display-control-panel,-nice-and-grace-looking-.
-
8.-muti-function-of-controller,-can-check-and-set-all-the-parameter-,multi-protection-and-alarming-function.
-
9,-use-soft-pipe-at-inlet-and-outlet-of-compressor,-so-that-avoid-vibratation-being-pass-on-other-pipes,-to-reduce-noise-and-avoid-welding-are-damaged-because-of-vibration.
10.evaperator-and-fan-motor-are-insulated-from-other-components-,-such-as-compressor,-condenser-and-son-on,-to-make-sure-other-components-will-not-touch-condensed-water-and-will-not-stained-fore-ever,
11.condensed-water-flow-down-to-ground-through-a-water-pipe,-the-pipe-connect-the-water-hole-at-the-middle-and-the-bottom-layer-plate.-so-that-condensed-water-will-be-drainged-at-once.
12.-use-insulation-for-compressor,-condenser-and-pipes,-make-sure-reduce-vibrate-and-noise-and-heat-loss.
13.-use-sinlencer-cotton-on-the-internal-wall-of-the-heat-pump,-to-reduce-noise-.
14.-R417/R407/R404-refrigerant,-environment-friendly.
16.-galvanized-steel-sheet-housing,-anticorrosive
-
Packing-and-delivery-:
1>packing-in-Plywooden-crate,-plastic-bag-inside-.
2>delivery-on-time-.-15-days-after-receive-deposit
2.Trade-term:air-to-water-heat-pump
1>-Packing:-Standard-Export-Packing-(Plywooden-case)
2>-Pay-term:-30%-T/T-Of-Total-value-as-deposit-to-start-the-produce,-And-70%-the-balance-before-shipping
3>-Delivery-time:-within-15-days-after-receive-the-deposit
4>-Effective-date:-The-price-validity-is-1-month
5>-Warranty:-14-months-Since-the-delivery-day
6>-Discount-will-be-offered-base-on-one-container
7>-MOQ=2
-
-
-
-