MC076S Motion Sensors On-off Control with Needle Antenna for LED Linear Batten Light
Input | Input Voltage | 198-264V AC 50Hz | |
Rated Input Voltage | 220-240V AC 50Hz | ||
Stand-by Power | ≤ 0.5W | ||
Output | Load Power | 250W (Inductive) 400W(Resistive) | |
Sensor Parameters | Hold Time | 5s/30s/90s/3min/20min/30min | |
Sensing Range | 100%/75%/50%/25% | ||
Daylight Sensor | Disable/50Lux/30Lux/10Lux/2Lux | ||
Mounting Height | Ceiling Mounting:2.5-4m | ||
Detection Area | Walking 0.5-1m/S keep walking≥2mwalk & stop≥5m | ||
Wireless Parameters | Operating frequency | 5.8 GHz ±75 MHz | |
control | 0N/0FF | ||
Operating Environment | Operating temperature | -25℃ - +60℃ | |
Storage temperature | -35℃~+80℃ Humidity : 85% (Non-condensing) | ||
Safety & EMC
| Isolation pressurization | N/A | |
EMC | EN55015 | ||
Certificate requirement | CE | ||
Others | Wiring method | Press fit terminal (4) | |
IP rating | IP20(Built-in) | ||
Protection Class | Class II | ||
Installation Size | 169*26*40mm | ||
Packaging requirement | Clapboard +Outer Carton (K=A) | ||
Life | 50000h |