Power Supply for DC Sensor with 1-10v Interface for Corridor Function MC103S
1. Features
■ Input 120-277Vac
■ Output 120-277Vac
■ Auxiliary output 12Vdc
■ Built-in relay,switch on/off power by relay
■ 1-10V interface for corridor function with sensor
■ 5 years warranty
2. Parameter
Input | Input Voltage | 108-305VAC |
Rated Voltage | 120-277VAC | |
Stand-by Power | ≤1W | |
Surge | L-N 1KV | |
Wiring | Press-in terminals 0.75-1.5mm2 | |
Output | Ouput voltage | 12Vdc |
Sensor Parameters | Working mode | ON/OFF,0-10V dimming |
Transmitting power | 0.5mW Max. | |
Load Capacity | 120V,50/60Hz,2A ballast 277V,50/60Hz 2A,ballast 220-240V,50/60Hz,2A Inductive | |
0-10V dimming | <50mA 10%(1.4-1.6V),20%(1.9-2.1V),30%(2.9-3.1V),50%(4.9- 5.1V) | |
Wiring | Press-in terminals 0.75-1.5mm2 | |
Operating Environment | Operating Temperature | -25℃…+60℃ |
Storage Temperature | Temperature: -40℃…+80℃; Humidity: 10%-95% (non-condensing) | |
EMC standards | EN55015, EN61000-3-2, EN61000-3-3, EN61547 | |
Safety standard | EN61347-1,EN61347-2-13 | |
Environmental Requirement | Compliant to RoHS | |
Certificate | CE pending | |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in/stand-alone | |
Dimension | 120x30x22mm | |
Package | cartons | |
Net Weight | 58g | |
Lifetime | 5 years warranty @Ta 230V full load |
3. Function (Below function is available only work with Merrytek DC sensor)
1) On/OFF Function (stand-by period be set to “0”s)
2) 2-step dimming function (stand-by period be set to “+∞”)
3) 3-step dimming function (stand-by period be set to “10S/1min/3min/5min/10min/30min”)
4. Dimension (mm)
5. Wiring
6. Wiring example when combined with Merrytek DC sensor
7. Application Notice
1) The sensor should be installed by a professional electrician. Please turn off the power before installing or wiring.
2) MC103S can only work with Merrytek DC sensor,please contact with Merrytek sales for right DC sensor model No.accroding to your application.