MC079D RC, DC Operation Sensor, 12/24V DC input, High Bay Sensor for Warehouse
1. Features
2. Parameter
Input | Operating Voltage Rage | N/A |
DC Input Voltage | 12/24V DC ±1V | |
Rated Voltage | 12/24V | |
No-load Power | N/A | |
Stand-by Power | <0.3W | |
Surge Test | N/A | |
Wiring | Leaded wire diameter: 22AWG | |
Output | Working Mode | 0-10V DC |
Type of Load | N/A | |
Load Capacity | N/A | |
Current of Load | N/A | |
Max. Surge Capacity | NA | |
Surge tet | NA | |
Wiring | Leaded wire diameter: 22AWG | |
Dim Interface | 1-10V Dimming | < 50mA (Non-constant source) |
Synchronous Control | N/A | |
High Low-level | N/A | |
PWM Control | N/A | |
Sensor Parameters | Operating Frequency | 5.8 GHz ±75 MHz,ISM Band. |
Transmitting power | 1mW Max. | |
Hold time | 5S/30S/1min/3min/5min/10min/20min/30min | |
Stand-by DIM Level | 10%(1.4-1.6V), 20%(1.9-2.1V), 30%(2.9-3.1V), 50% (4.9-5.1V) | |
Stand-by Period | 0s/10S/1min/3min/5min/10min/30min/+∞ | |
Detection Area | 25%/50%/75%/100% | |
Daylight Sensor | 5lux/15Lux/30Lux/50Lux/100lux/150lux/Disable | |
Detecting Radius | See detection pattern | |
Mounting Height | 15m Max | |
Detecting Angle | 150°(wall mounting) 360°(ceiling mounting) | |
Wireless Module | Operating Frequency | N/A |
Transmitting power | N/A | |
Transmitting distance | N/A | |
Modulation mode | N/A | |
Number of coding | N/A | |
Operating Environment | Operating Temperature | -35℃…+70℃ |
Storage Temperature | Temperature: -40℃…+80℃; Humidity: 10%-95% (non-condensing) | |
Certificate Standards | Safety standards | EN60669-2-1, EN60669-1 |
EMC standards | EN55015, EN61000-3-2, EN61000-3-3, EN61547 | |
Environmental Requirement | Compliant to RoHS | |
Certificate | CE | |
Others | Wiring | UL21996,3*22AWG, exposed line length: 300mm |
IP Rating | IP65 | |
Protection Class | Class II | |
Installation | External mounting | |
Dimension | ¢55*41mm | |
Package | Instruction+ White box+ White box tags+ Clapboard+ Carton(K=A) | |
Net Weight | 65g | |
Lifetime | 50,000h @ Ta Full load | |
Note 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s. |
3. Function
1) On/OFF Function (stand-by period be set to “0”s)
2) 2-step dimming function (stand-by period be set to “+∞”)
3) 3-step dimming function (stand-by period be set to “10s/1min/3min/5min/10min/30min”)
4. Dimension (mm)
5. Wiring
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
6. Remote Control
Toggle button can set the remote control distance of 5m /10m /15m.