LED Emergency Driver Power 3W Emergency Time 3h & Built-in Li-ion Battery KE002-03M180KB
1. Features
--Constant power output LED emergency power supply, max 3W emergency power, and wide output voltage range.
--Multiple protection function: battery over charge , deep discharge, output overload and short-circuit protection.
2. Parameters
Charge Part | Rated input voltage | 220-240Vac 50Hz /60Hz |
Rated input current | 0.1A Max.@230Vac | |
Input inrush current | 30A(230Vac full load) | |
Power factor | ≥0.5W @230Vac | |
Input power | <2W@230Vac | |
Battery charging current | 240mA | |
Battery charging time | 24 hours Max. | |
Emergency Part | Operating mode | Emergency |
Load type | LED | |
Emergency power | 3W Max. | |
Emergency time | 3 hours | |
Load output current | 180-20mA | |
Load output voltage | 20-60Vdc | |
Battery | Type | Li-ION: 3.7V 3350mAH |
Exception Driver Requirements | Surge current | N/A |
Input current | N/A | |
Output current | N/A | |
LED Indication | Charging | The green light turns on |
Fault | The green light switches off | |
Emergency Function Test | Manual test | Yes |
Auto test | N/A | |
Connect Control | Bluetooth | N/A |
DALI | N/A | |
Abnormal Protection Requirements | Battery over-charge/deep discharge protection | Yes |
Output over-voltage protection | Yes | |
Output overload protection | Yes | |
Output no-load protection | N/A | |
Output over-temperature protection | N/A | |
Output short circuit protection | Yes | |
Operating Environment | Operating temperature/humidity | 0℃…+50℃ humidity:20%-85%(without condensation) |
Storage temperature/humidity | -5℃…+45℃ | |
Case Max. Temp(Tc) | 75℃ | |
Safety & EMC
| Withstand voltage | 3750Vac 5mA 60S(Input “L N” – output “SEC+ SEC-) |
Safety standard | EN61347-1, EN61347-2-7 | |
EMC standard | EN55015, EN61000-3-2, EN61000-3-3 | |
Battery standard | EN61233 | |
Environmental protection requirements | Compliant to RoHS | |
Certification | CE | |
Others | Input/output(terminal/wiring) type | Press terminal, wire diameter:0.5-0.75mm2 |
IP rating | IP20 | |
Type of protection | Class 2 | |
Installation type | Built-in installation | |
Installation dimension | 137*42*22mm | |
Packaging requirement | Bubble bag+ clapboard +outer carton(K=A) | |
Weight | 111g | |
Lifespan | Emergency driver 30000h @Ta full load (Driver) | |
Notes: All parameters are tested on the input voltage 120/230Vac,environment temperature 25℃,unless otherwise specified. |
3. Dimension (Unit:mm)
4. Wiring Diagram
5. Function
6. Wire Preparation
1)Solid or Stranded wire type 0.5 - 0.75mm2
2)To make or release the wire from the terminal, use a screwdriver to push down the button.
7. Manual Test & Operation Instructions
1) Connect the wire according to wiring diagram.
2) L,N power on, switch on E. Then the load lamp turns on, the emergency driver indicator light will turns green, emergency power supply normal charging. Turn off this switch E, the load lamp will be extinguished.
3) Emergency Simulation: Switch on E, the load lamp turns on, press the switch(TEST SWITCH), then switch to emergency mode, the indicator light of emergency driver will be extinguished. Release the switch(TEST SWITCH), then lamp is powered by led driver, the indicator light will turn on.
4) Power off and power on, the phenomenon should be similar to emergency simulation.
8. Battery Application Notice
1) The battery should be recharged and discharged semiannually in normal use conditions.
2) Do not connect to the circuit when the battery is not use to prevent over-discharge of the battery due to self-consumption of the circuit board.
3) Please keep the battery from the heat source when installing and using, and only be allowed to use in certain working temperature range.
4) The battery should be stored in a cool and dry environment.
5) After long time storage, the battery is cycled every 6 months as required.
6) If you don’t use for a long time(for example, in transport or in a warehouse), please press the REST button.