IP20 Flush Mounted Standalone Microwave Motion Sensor to use in commercial building corridor
1. Features
1) Low impedance sensor antenna patent helps anti-interference of kinds of wireless signals like 5G, Wi-Fi, Bluetooth, etc.
2) Parameters can be set by the DIP switch.
3) Compact size for Independent flush mounting.
4) Switching power supply design, complies with ERP directive.
2. Parameters
Input | Operating Voltage Range | 198-264V AC 50Hz/60Hz |
Rated Voltage | 220-240V AC 50Hz/60Hz | |
Stand-by Power | ≤0.5W | |
Surge Test | L--N: 1kV | |
Output | Working Mode | ON/OFF function |
Type of Load | Inductive or Resistive Load | |
Load Capacity | 800W (Resistive), 400w(Inductive) | |
Max. Surge Capacity | 15A relay 30A (50% Ipeak, twidth = 500uS@230Vac full load, cold start); | |
Sensor Parameters | Operating Frequency | 5.8 GHz ±75 MHz,ISM Band. |
Transmitting Power | 0.5mW Max. | |
Hold Time | 5S/1Min/5Min/10Min | |
Detection Area | 100%/75%/50%/25% | |
Daylight Sensor | 5lux/30lux/50lux/Disable (diffuse state) | |
Detecting Area (radius) | ≥3m | |
Mounting Height | 2.5-4m | |
Detecting Angle | 120° | |
Operating Environment | Operating Temperature | -25℃…+50℃ |
Storage Temperature | Temperature: -40℃…+80℃; Humidity: 10%-95% (non-condensing) | |
Certificate Standards | Safety Standards | EN60669-1 EN60669-2-1 |
EMC Standards | EN300440 EN301489-1 EN55015 EN61547 EN62479 | |
Environmental Requirement | Compliant to RoHS | |
Certificate | CE, RED, SAA | |
Others | Wiring | screw type terminals, wire diameter: 0.75-1.5mm2 |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Flush-mounted | |
Cut size | Φ55mm-Φ60m | |
Package | White box+ White box tags+ Clapboard+ Carton(K=A) | |
Lifetime | 5 years warranty @Ta 230V full load | |
Note: The detection range of the sensor is related to the moving speed and size of moving object, mounting height, installation height and angle, installation site, reflectors around the sensor etc. The data in the document is typical value and tested by a 165cm person in an open indoor area. The detection range at wall mounting will be longer at ceiling mounting. Please reduce detection sensitivity at wall mounting or contact us to confirm the sensor data settings. |
3. Dimension
4. Wiring Diagram
5. Start Process & Initialization
When powered on, the light will turn on for 10 seconds. The sensor does not detect moving signals during initialization.
6. Factory Settings
Detection Area: 100% Hold Time: 5s Daylight Sensor: Disable
7. Installation Instruction
8. Application Notice
1. The product should be installed by a professional electrician. Please turn off the power before installing, wiring, or changing the setting of the DIP switch.
2. The product has good penetration ability to plastic and wooden objects, but there should be no metal accessories or metal shells, glass shells, etc. In front of and near the antenna of the microwave module, otherwise, it will affect the transmission and reception of the microwave antenna.
3. The product is only suitable for indoor installation. During semi-outdoor or outdoor installation, wind and rain may be regarded as mobile signals to trigger the sensor.
4. The detection distance is related to the moving speed of the moving object, the size of the moving object, the installation height, the installation angle, whether the installation environment is empty, the material of the reflector, and other factors. The detection distances given in the specification are typical values, which are obtained by testers at a height of 165cm and weight of 65kg and tested in an indoor open environment. The detection area of the wall installation will be greatly increased compared with ceiling installation. If wall installation is used, please reduce the sensitivity or contact us to confirm the use setting.
5. Avoid long-term vibrating equipment or moving objects around the sensor, and the vibration signal will be regarded as a moving signal to trigger the sensor.
6. If a pet passes by in the detection area, the sensor may be triggered.
7. The daylight thresholds are measured on a sunny day without shadow and in an ambient light diffuse reflection status. Different environments and climates cause different brightness values that daylight sensors measure.
8. The installation distance between the product and the router is recommended to be greater than 2m, and the installation distance between the product and the router is recommended to be greater than 2m.
9. The installation plane of the product(for example: aluminum substrate, PCB board)needs to be different from the antenna plane of the microwave module by a certain height. The antenna plane of the microwave module should be higher than the nearby plane by more than 5mm to achieve the best detection effect.
9. DIP Settings
Detection Area
1 | 2 | |
100% | ON | ON |
75% | - | ON |
50% | ON | - |
25% | - | - |
Hold Time
3 | 4 | ||
Ⅰ | ON | ON | 5S |
Ⅱ | - | ON | 1 Min |
Ⅲ | ON | - | 5 Min |
Ⅳ | - | - | 10 Min |
Daylight Sensor
5 | 6 | ||
Ⅰ | ON | ON | 5Lux |
Ⅱ | ON | - | 30Lux |
III | - | ON | 50Lux |
Ⅳ | - | - | Disable |
*When set to “disable”, the lamp will switch on when it detects the motion no matter the ambient light level.
10. Remote Control