ADVANCED SENSOR PIPE SECTION MULTIPHASE FLOW CONE SEAL MF ELECTROMAGNETIC FLOWMETER
- The flow measurement range is wide, and the range ratio is 1500:1.
- The flow rate of minimum guaranteed accuracy is 0.2m/s.
- Advanced sensor technology can ensure that the installation of straight pipe section takes only 1.6D.
- High accuracy: up to 0.2% indicating value
- Forward and backward flow are measurable: pulse flow, multiphase flow and slurry are measurable.
- The input of the converter is more than 1012 ohms, which can effectively prevent the influence of scaling on the sensor, and the minimum conductivity can reach 1.7us/cm.
- The electrode seal adopts a unique double-sided sealing method of cone seal and line seal.
- Buried installation and long-term immersion installation are allowable, up to IP68.
- Multi-frequency excitation technology/DSP digital processing technology/high frequency sampling technology/data coordinating analysis technology
- Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage)
Main Ttechnical Pparameters:
Flow Master MFE-S type electromagnetic flowmeter | | | One type | split type | Basic error | ± 0.2% or ± 0.5% of the indicated value | caliber (mm) | DN2.5~DN2400 | DN2.5~DN2400 | flange | Comply with gb9119 standard, carbon steel (optional stainless steel) | Pressure class | DN2.5~DN600 1.0 1.6 2.5 4.0MPa DN700~DN2400 0.6MPa The special pressure shall be determined through consultation with the company | Lining material | PTFE polytetrafluoroethylene, polyurethane rubber, PFA, F46, natural rubber, neoprene, ETFE | conductivity | ≥5μS/CM(Less than ≥ 5 μ S / cm negotiates the order with our company ) | electrode | 316L, Hastelloy, titanium, tantalum, platinum iridium alloy, tungsten carbide | Degree of protection | IP65 | IP65(Sensor optional IP68) | Medium temperature | -25℃~80℃ See lining material selection for details | -25℃~140℃ See lining material selection for details | ambient temperature | -25℃~60℃ | Influence of ambient temperature | <±0.1%/10℃or<±0.25%/10℃ | Repeatability and repeatability | ≤±0.1%or±0.25% | Analog output error | ≤±0.02mA | Measuring range flow rate | ≤20m/s | Embedability | ------------ | ≤5m(Only IP68) | Electrical connection | M20*1.5Sealing sleeve,G1/2,NPT1/2 | Sensing cable | ------------ | If it is too long, you need to negotiate with our company to order | Output interface* | Standard output (pulse + 4 ~ 20mA single current output), dual current output, RS485,HART,Profibus-PA | Note*: 4-20mA analog output is active output |
Application Scenarios: