ADVANCED SENSOR PIPE SECTION MULTIPHASE FLOW CONE SEAL MF ELECTROMAGNETIC FLOWMETER
- The flow measurement range is wide, and the range ratio is 1500:1.
- The flow rate of minimum guaranteed accuracy is 0.2m/s.
- Advanced sensor technology can ensure that the installation of straight pipe section takes only 1.6D.
- High accuracy: up to 0.2% indicating value
- Forward and backward flow are measurable: pulse flow, multiphase flow and slurry are measurable.
- The input of the converter is more than 1012 ohms, which can effectively prevent the influence of scaling on the sensor, and the minimum conductivity can reach 1.7us/cm.
- The electrode seal adopts a unique double-sided sealing method of cone seal and line seal.
- Buried installation and long-term immersion installation are allowable, up to IP68.
- Multi-frequency excitation technology/DSP digital processing technology/high frequency sampling technology/data coordinating analysis technology
- Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage)
Main Technical Parameters:
Flow Master MFE-S type High protection electromagnetic flowmeter | | | | split type | One type (IP67) | Explosion proof integrated type | Basic error | ± 0.2% or ± 0.5% of the indicated value | | caliber (mm) | DN2.5~DN2400 | DN2.5~DN2400 | Explosion proof grade | ------------ | Exia/de Ⅱ CT4 Ga/Gb | flange | Comply with gb9119 standard, carbon steel (optional stainless steel) | Pressure class | DN2.5~DN600 1.0 1.6 2.5 4.0MPa DN700~DN2400 0.6MPa The special pressure shall be determined through consultation with the company | DN2.5~DN600 1.0 1.6 2.5 4.0MPa The special pressure shall be determined through consultation with the company | Lining material | PTFE polytetrafluoroethylene, polyurethane rubber, PFA, F46, natural rubber, neoprene, ETFE | conductivity | ≥5μS/CM(Less than ≥ 5 μ S / cm negotiates the order with our company ) | electrode | 316L, Hastelloy, titanium, tantalum, platinum iridium alloy, tungsten carbide | Degree of protection | IP67(Sensor optional IP68) | IP67 | Medium temperature | -25℃~140℃ See lining material selection for details | -25℃~80℃ See lining material selection for details | ambient temperature | -25℃~60℃ | Influence of ambient temperature | <±0.1%/10℃or<±0.25%/10℃ | Repeatability and repeatability | ≤±0.1%or±0.25% | Analog output error | ≤±0.02mA | Measuring range flow rate | ≤20m/s | Embedability | ≤5m(Only IP68) | ----------- | Sensor cable | <100m If it is too long, you need to negotiate with our company to order | ----------- | Electrical connection | M20*1.5Sealing sleeve,G1/2,NPT1/2 | Output interface* | Standard output (pulse + 4 ~ 20mA single current output), dual current output, RS485,HART,Profibus-PA | Note*: 4-20mA analog output is active output |
Product performance
·The simple measured current output is used to display the flow, and the pulse output is used to drive the external accumulator or as the status output
·Can ensure the reliability, safety and stability of measured values of all basic functions
·The optimized process control accuracy is + 0.5%
·PTFE lining ensures maximum corrosion resistance and temperature resistance up to 130 ℃
·It can be assembled under most difficult conditions (such as shaft, vibration or long-term underwater). The sensor can be installed independently without sensor, and the protection level is IP68
·The functional design makes maintenance simple and easy. Hart, fieldtool and fieldcheck provide support for equipment verification, so there is no need to move the sensor
Application Scenarios: