Specifications
Brand Name :
GENY
Model Number :
YC98S1
Certification :
ISO, CE
Place of Origin :
China
MOQ :
1
Price :
negotiate rates
Payment Terms :
T/T,L/C,D/P,T/T
Supply Ability :
50 pcs/ 1 months
Delivery Time :
6~8weeks
Packaging Details :
Plywood cases
Brand :
GENY
Model :
YC98S1
Accuracy class :
0.05% / 0.2%
Test Voltage :
0~500V
Test Current :
12A direct / 5A / 100A / 1000A / 2000A indirect
Description

Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

YC98S1 Portable 3 Phase Standard Meter


The instrument YC98S1 is used to calibrate three phase, single phase, active or reactive energy
meter who comply with GB/T17215.211 (IEC62052-11), GB/T17215.311 /321/322/323
(IEC62053-11/21/22/23), and also it can be used as voltage, current and power meter to measure
AC parameter of three phase power grid.

This portable three phase standard meter comply to GB/T11150-2001 (IEC60736:2001),
GB/T4793.2-2008 (IEC61010-1:2001).

Test functions


  1. Can test one meter or two meters at the same time.
  2. Automatic test sequence using the scanning head for electronic and electromechanical meters
  3. Can synchronously calculate all data and display on the interface include full wave
  4. Can test active and reactive energy accuracy of full wave meter
  5. Can simultaneously test two channel pulses whose pulse constant
  6. Wiring identification is available when no load.
  7. Electric energy accumulation function can measure the electric energy meter when it has not pulse output.
  8. Dial test function
  9. Display vector diagram
  10. Can identify wrong wiring (48 types connections)
  11. Instrument can be simulate the scene of variety of wiring and get corresponding the result of wiring and revised parameter in office without access to voltage or current signal situation
  12. Harmonic functions


Specifications

Error (100AClamp CT)

±0.2%(5A,100A) ±0.5% (other)

Harmonic

2nd ~ 51st

Starting current

0.05%Ie

Power Measure Error (Full Wave & Fundamental Wave)

Active Power (Direct connection)

±0.05%

Active Power (100A ClampCT)

±0.2%(5A,100A) ±0.5% (other)

Reactive Power (Direct connection)

±0.1%

Reactive Power (100A ClampCT)

±0.5%(5A,100A) ±1.0% (other)

Energy Measure Error (Full Wave & Fundamental Wave)

Active Energy (Direct connection)

±0.05% (±0.1%)

Active Energy (100A ClampCT)

±0.2%(5A,100A) ±0.5% (other)

Reactive Energy (Direct connection)

±0.1%

Reactive Energy (100A ClampCT)

±0.5%(5A,100A) ±1.0% (other)

Error (Harmonic Wave)

Direct Connection

kWh,U, I, P, Q, S

±0.2%H (H=1+0.01k, k=2~51)

Clamp CT

kWh,U, I, P, Q, S

±0.5%H (H=1+0.01k, k=2~51)


5A/100A

Cycle Output Current for 5A CCT’s Self Calibration

0.05A,0.1A,0.25A,0.5A,1A,2.5A,5A

Error of 5ACCT’s Self Calibration

±0.1%


(linear and phase error)

Clamp CT 500A/1000A

kWh,U, I, P, Q, S

±1.0%H (H=1+0.01k, k=2~51)

Error - Others

Ratio Measurement

±0.5%

Voltage Influence

<±0.01%

Frequency Influence

<±0.01%

Temperature Influence

<±0.01%/℃

24h Accuracy Influence

<±0.01%

Harmonic Influence

<±0.01%

Phase angle

Range

- 180°~ 180°

Error

<±0.1°

Frequency

Range

45 ~ 65Hz

Error

±0.01Hz

Pulse output

Inner High frequency (CH)

1.8x109 P/kWh

1.8x109 *(5/Ie)P/kWh

Low frequency output

3600P, 36000P,


360000P/kWh(kvarh, kVAh)

3600P, 36000P,


360000P


*(5/Ie)P/kWh(kvarh, kVAh)

Pulse ratio

1:01

Output level

+5V (can be adjusted according to request)

Pulse input

Input Channel

2

Input level

5 ~ 10V

Max Pulse Input frequency

Max. 10kHz

Display

Resolution

7’’TFT Touch Screen

System

Windows CE

Other

Voltage supply mode

External power, Tested circuit, Battery

Working power supply

AC 55~600V

Voltage Withstand

4.0kV (voltage ¤t terminals, power supply & low voltage terminals)

EFT(Electrical Fast Transient)

2.0kV

IP Level

IP51

Surge

2.0kV (common mode), 2.0kV (different mode)

Power on Stability Time

< 3mins

Chargeable battery

11.1V 3000mAh

Power Consumption

<9W

Operation Temperature

Temperature -20℃ ~ +55℃, humidity 40% ~ 95%

Storage Temperature

Temperature -40℃ ~ +80℃, humidity 40% ~ 95%

Dimension (mm) (W×H×D)

Main

245×150×50

Carry case

425×336×196

Weight (kg)

Main

2

Whole set

10


Portable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current MeasurementPortable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

*If you want to know more please check our official website:http://www.genymetertestequipment.com/

Send your message to this supplier
Send Now

Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

Ask Latest Price
Watch Video
Brand Name :
GENY
Model Number :
YC98S1
Certification :
ISO, CE
Place of Origin :
China
MOQ :
1
Price :
negotiate rates
Contact Supplier
video
Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement
Portable Three Phase Meter Calibrator for Accurate Voltage and Current Measurement

Guangzhou GENY Electric Co., Ltd

Verified Supplier
2 Years
guangzhou
Since 1987
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
2,000,000-10,000,000
Employee Number :
50~100
Certification Level :
Verified Supplier