Specifications
Certification :
ISO, CE
Supply Ability :
100/Year
Payment Terms :
L/C, T/T, D/P
Brand Name :
GENY
Model Number :
YC1893D
Place of Origin :
CHINA
Model NO. :
YC1893D-24 Three Phase Meter Test System
Display :
Digital
Installation :
Direct Connected
Usage :
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment :
Three-phase Three-wire
Theory :
Electronic Meter
Power Meter Connection :
Terminal
Measured Signal :
Pulse Peak
Type :
Energy Meter
Customized :
Customized
Trademark :
GENY
Transport Package :
Plywood Case
Specification :
12.4CBM
Origin :
China
HS Code :
9030849000
Port :
Guangzhou, China
Description

Yc1893D-24 Digital Three Phase Energy Meter Test System for Versatile Applications

Description

GENY’s meter test systems adopt the most advanced electronic measurement technique, and modular concept, combining the different reference standards and power amplifiers to satisfy customers’ requirements in electric energy meter manufacturers, electric power utilities, metrology laboratories, measuring and quality examining departments, and factories or enterprises.

The MTS is a full-automatic test system for calibration and verification of three-phase electric energy meters, which composes of:

  • Three-phase static power source
  • Three-phase reference standard meter
  • Meter automatic suspension test rack
  • Other necessary parts
  • PC and software controlling the whole system

The YC1893D series meter test systems is fully compliant with the IEC 60736 standard and is suitable for testing meters according to the following standards:

  • IEC 62052-11 and IEC 62053-11, -21, -22, -23, -24
  • IEC 62056
  • EN 50470-1, EN 50470-2, EN-50470-3
  • IEC 61010

Features and functions

The MTS mainly has features below

  • Supporting parallel communication port to test smart meters through RS232
  • Calibrating terminals on the rack for test bench verification
  • Suit for calibration/verification of 3-phase energy meters of Landis+Gyr
  • Accuracy testing of reference standard meter
  • Pre-warming
  • Accuracy test as per IEC
  • No-load test
  • Starting current test
  • Repeatability of error test
  • Dial test (register test)
  • Clock frequency accuracy test of electricity meters
  • Maximum demand test
  • Influence quantity test related to accuracy tests (Voltage, Frequency, reverse phase sequence, voltage unbalance)
  • Influence of harmonic components in voltage and current circuit as per IEC
  • Sub Harmonics as per IEC standards (IEC 62052-11 / 62053-21/22/23)
  • Odd Harmonics as per IEC standards (optional)

Customized features:

  • Automatic wiring function for each station
  • All stations have automatic short circuit function
  • Custom quick connection device QCD for Landis+Gyr ‘s meters
  • PC software development for ESAM testing

Technical Data

1. Power Supply

Voltage 3 × 220V±10%
Frequency 50 / 60Hz ± 2Hz
Power capacity >6k VA
Ambient temperature -10°C -- +40°C
Relative humidity 35% -- 85%

2. Power Source

Voltage output
Test voltage output (Phase-Neutral) 3 × (24V – 300V)
Power of the voltage output 3 × 1000VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Current output
Test current output 3 × (0.3mA – 20A)
Power of the current output 3 × 1500VA
Resolution Better than 0.01% of full scale value of range
Setting accuracy Better than 0.05% at the final range value
Stability Better than 0.005%/h (integration time 150 s)
Load regulation from 0-max. load Better than 0.01%
Distortion factor Better than 0.3% for linear resistance load
Harmonics 2nd – 21st free programmable
Phase angle
Range 0 -- 360°
Resolution 0.01°
Setting accuracy 0.1°
Frequency
Range 45Hz – 65Hz
Resolution 0.01Hz

Yc1893D-24 Three Phase Meter Test Bench Energy Meter Test System

Send your message to this supplier
Send Now

Yc1893D-24 Three Phase Meter Test Bench Energy Meter Test System

Ask Latest Price
Certification :
ISO, CE
Supply Ability :
100/Year
Payment Terms :
L/C, T/T, D/P
Brand Name :
GENY
Model Number :
YC1893D
Place of Origin :
CHINA
Contact Supplier
Yc1893D-24 Three Phase Meter Test Bench Energy Meter Test System

Guangzhou GENY Electric Co., Ltd

Verified Supplier
2 Years
guangzhou
Since 1987
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
2,000,000-10,000,000
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement