YCS-101 Single Phase Power Source
YCS-101-250 | YCS-101-600 | YCS-101-1200 | YCS-101-2500 | |
Voltage | ||||
Test voltage output (Phase-Neutral) | 24V – 288V or customized | |||
Power of the voltage output | 100VA | 250VA | 500VA | 1000VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Current | ||||
Test current output | 1mA – 100A | |||
Power of the current output | 150VA | 350VA | 750VA | 1500VA |
Resolution | Better than 0.01% of full scale value of range | |||
Setting accuracy | Better than 0.05% at the final range value | |||
Stability | Better than 0.005%/h (integration time 150 s) | |||
Load regulation from 0-max. load | < 0.01% | |||
Distortion factor | < 0.3% for linear resistance load | |||
Harmonics | 2nd – 21st free programmable | |||
Phase angle | ||||
Range | 0 -- 360° | |||
Resolution | 0.01° | |||
Setting accuracy | 0.1° | |||
Frequency | ||||
Range | 45Hz – 65Hz | |||
Resolution | 0.01Hz | |||
Voltage Supply | 220V±10% or 50/60Hz±2Hz | 3×220/380V±10% or customized 50/60Hz±2Hz | ||
Ambient temperature | -10°C -- +40°C | |||
Relative humidity | 35% -- 85% |
In the domestic market of electric measurement products, our marketing occupation share is around 30%. Many state-owned large-sized utilities and power-supply bureaus are our constant clients. It is due to the excellent quality of our products and the good after-sales service that we offer.
During the past years, we have made great efforts in exploring the overseas market, which yielded fruitful results. Today our products reached many places in the world(over 30 countries)and our important customers include Actaris, Landis&Gyr, EATON, Schlumberger, Secure Meters, EMCO, NAMJUN, LEMZ, etc.