Technical spec. | |
Number of meter positions | 24 |
Accuracy | 0.05 / 0.02 |
Power Source | YCS-103-1200 |
Standard Meter | SZ03A-K6 / SZ03A-K8 / Radian RD-33 |
Scanning Head | YCG-S Series |
Voltage | |
Test voltage output(Phase-Neutral) | 3* (24V~288V)(or customized) |
Power of the voltage output | Max. 3x500VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Current | |
Test current output | 3* (1mA - 100A) |
Power of the current output | Max. 3x750VA |
Resolution | Better than 0.01% of full scale value of range |
Setting accuracy | Better than 0.05% at the final range value |
Stability | Better than 0.005% /h (integration time 150s) |
Load regulation from 0~max. load | Better than 0.01% |
Distortion factor | Better than 0.3% for linear resistance load |
Harmonic | 2nd~21st free programmable |
Phase angle | |
Range | 0~360⁰ |
Resolution | 0.01⁰ |
Setting accuracy | 0.1⁰ |
Frequency | |
Range | 45Hz~65Hz |
Resolution | 0.01Hz |
Error display | |
Type of error display | Red LED |
Resolution of error displays | 8 digitals |
Other | |
Voltage supply | 3x220/380V±10%(or customized) 50/60Hz ±2Hz |
Ambient temperature | -10°C~+40°C |
Relative humidity | 35%~85% |
1. Nation-level utility companies
2. Governmental bureaus of metrology
3. Big energy meter manufacturers
· High quality product
· Over 18 months long warranty
· High accuracy class: 0.02/ 0.05/ 0.1
· Can be customized of Three Phase Electric Energy Meter Test bench
· Extremely high power stability
· Timing Error Test
· Neutral current test(optional)
· Installing RS232, Ethernet communication port in each meter position.
· Influence test of voltage, frequency, and harmonic