Environment | Safety | ||||
Operation Temperature | Relative Humidity | Relative Humidity | Altitude | IP Class | Conformity |
-10℃-55℃ | 5%-95% | 5%-95% | <2500m | 40 | IEC |
Model | YC-2000N | YC-2000C | |||
Test Voltage | |||||
Range | 00~275V(test leads 0~300V(battery) | 5~380V | |||
Error | ±0.1% | ±0.2%/0.5% | |||
Harmonics | 2nd~51st | 1st-31st | |||
Test Current | |||||
Range(Direct mode) | 10A | - | |||
Error(Direct mode) | ±1% | - | |||
Range(Clamp-on CT) | 5/10A,20A,50A,100A | 100A | |||
Error(Clamp-on CT) | ±0.2% | ±1.2%/0.5% | |||
Harmonics | 1st~51st | 1st-31st | |||
Power Energy Measurement Error | |||||
Active(Clamp-on CT) | ±0.2% | ±0.2%/±0.5% | |||
Reactive(Clamp-on CT) | ±0.5% | ±0.5%/±1.0% | |||
Phase Angle | |||||
Range | 0°~360° | 0°~360° | |||
Error | ±0.1° | <±0.05° | |||
Frequency | |||||
Range | 45~65Hz | 45~65Hz | |||
Error | ±0.01Hz | ±0.005Hz | |||
Pulse Output | |||||
High Frequency | 3.6x10^8 imp/kW.h | 3.6x10^8 imp/kW.h | |||
Low Frequency | 7200 imp/kW.h | 72(0 imp/kW.h | |||
Pulse ratio | 1:01 | 1:01 | |||
Output level | 4.5~5.5V | 4.5~5.5V | |||
Pulse Input | |||||
Input Level | DC 4.5~12V | DC 4.5~12V | |||
Input Frequency | Max.10kHz | Max.10kHz | |||
Others | |||||
Power Supply | Test voltage, battery (optional) | Battery | |||
Display | 5° TFT touch screen(800*480) | Colorful touch screen | |||
Data Storage | 2000 sets | 999 sets | |||
Dimension | 215mm x 120mm x 52mm | 195mm×80mm x 35mm | |||
Weight | 1KG | 0.4KG |