Specifications
Brand Name :
GENY
Model Number :
YC99T-3C/5C
Certification :
ISO, CE
Place of Origin :
CHINA
Payment Terms :
L/C, T/T, D/P
Supply Ability :
50/Year
Model NO. :
YC99T
Display :
Digital
Installation :
Direct Connected
Usage :
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Electric Equipment :
Three-phase Three-wire
Theory :
Electronic Meter
Power Meter Connection :
Terminal
Measured Signal :
Continuous Wave
Type :
Energy Meter
Customized :
Customized
Trademark :
GENY
Transport Package :
Plywood Case
Specification :
0.5CBM
Origin :
China
HS Code :
9030849000
Port :
Guangzhou, China
Description

Portable Meter Test System for and AC Voltage Current Power Phase and Frequency Output

Specification

Model No.YC99T-3C
Meter Position / Accuracy3 / 0.05
AC Voltage output
Range57.7V,100V, 220V, 380V 660
Adjustment Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion0.2% (Non capacitive load)
Max Output load20VA/phase
Measurement Accuracy%0.05%RG(0.05cl), %0.1%RG(0.1cl)
AC Current output
Range0.05A 0.2A 1A 5A 16.67A 50A
Adjust Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion0.2% (Non capacitive load)
Max Output load50VA(50A range)
Measurement Accuracy%0.05%RG(0.05cl), %0.1%RG(0.1cl)
Power output
Stability0.01%/2min(0.05cl), 0.02%/2min(0.1cl)
Active, Reactive power accuracy%0.05%RG
Phase output
Output adjusting range0 ~ 359.99
Output adjusting power10°,1°,0.1°,0.01°optional
Resolution0.01
Measurement accuracy%0.05
Power factor output
Adjusting range-1~0~+1
Measuring resolution0.0001
Measurement accuracy%0.0005
Frequency output
Adjusting range40Hz – 70Hz
Output adjusting resolution1Hz, 0.1Hz, 0.01Hz, 0.001Hz optional
Resolution0.001Hz
Accuracy%0.002Hz
Harmonic setting
Harmonic order2nd~63rd
Harmonic amplitude0~40%
Harmonic angle0 ~359.00
Harmonic set error2nd ~ 31st : %0.1%, 32nd~63rd: %0.2%
Energy error measurement
Active energy basic error limit%0.05%RD(voltage30V~660V,current0.02A~60A,PF 0.5)
Reactive energy basic error limit%0.1%RD(voltage30V~660V,current0.02A~60A,PF 0.5)
Standard crystal
Frequency accuracy%0.5ppm (leave factory@25 )
Frequency stability%0.1ppm,-20 ~+70
Energy pulse input
Number of energy pulse input3 channels active, 3 channels reactive
General parameters
Power supplyAC220V%15% or 110V%15%
Frequency50Hz~60Hz
Consumption60VA~1000VA
Environment condition20 ~ 30 relative humidity
Storage environment-20 ~50
Size & Weight600mm(L) 400mm(W) 266mm(H), 30kg

Model No.YC99T-5C
Meter Position / Accuracy3 / 0.05cl
AC Voltage output
Range57.7V,100V, 220V, 380V
Adjustment Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion0.2% (resistance load)
Max Output load20VA/phase
Measurement Accuracy%0.05%RG(0.05cl), %0.1%RG(0.1cl)
AC Current output
Range0.05A 0.2A 1A 5A 20A 100A
Adjust Range(0-120)%RG (RG is Range)
Adjust Resolution0.01%RG, 0.1%RG, 1%RG, 10%RG(optional)
Stability0.01%/2min (0.05cl), 0.02%/2mim(0.1cl)
Distortion0.2% (Non capacitive load)
Max Output load100VA(100A range)
Measurement Accuracy%0.05%RG(0.05cl), %0.1%RG(0.1cl)
Power output
Stability0.01%/2min(0.05cl), 0.02%/2min(0.1cl)
Active, Reactive power accuracy%0.05%RG
Phase output
Output adjusting range0 ~ 359.99
Output adjusting power10°,1°,0.1°,0.01°optional
Resolution0.01
Measurement accuracy%0.05
Power factor output
Adjusting range-1~0~+1
Measuring resolution0.0001
Measurement accuracy%0.0005
Frequency output
Adjusting range45Hz – 70Hz
Output adjusting resolution1Hz, 0.1Hz, 0.01Hz, 0.001Hz
Resolution0.001Hz
Accuracy%0.002Hz
Harmonic setting
Harmonic order2nd~63rd
Harmonic amplitude0~40%
Harmonic angle0 ~359.99
Harmonic set error2nd ~ 31st : %0.1%, 32nd~63rd: %0.2%
Energy error measurement
Active energy basic error limit%0.05%RD(voltage30V~380V,current0.02A~120A,PF 0.5)
Reactive energy basic error limit%0.1%RD(voltage30V~380V,current0.02A~120A,PF 0.5)
Standard crystal
Frequency accuracy%0.5ppm (leave factory@25 )
Frequency stability%0.1ppm,-20 ~+70
Energy pulse input
Number of energy pulse input3 channels active, 3 channels reactive
General parameters
Power supplyAC220V%15% or 110V%15%
Frequency50Hz~60Hz
Consumption60VA~1000VA
Environment condition20 ~ 30 relative humidity
Storage environment-20 ~50
Size & Weight600mm(L) 400mm(W) 266mm(H), 48kg

Simple Description

It is used in the measurement testing center of the grid companies, measurement department of power supply companies and power plants, national measurement testing institutions and metrology inspection departments, measurement testing departments of medium-sized enterprises, such as railway and petrochemical. Also, it can be used by the manufacturers of energy meters, includes its production, research and development, testing departments, as well as in universities and related research institutions, specialized laboratories.
The meters user can calibrate including : Single-phase active energy meter, three-phase three-wire active energy meter, three-phase three-wire composite meter, three-phase four-wire active energy meter, three-phase four-wire composite meter, three-phase three-wire sine reactive energy meter, three-phase four-wire sine reactive energy meter, two elements 60° reactive energy meter, two elements 90° reactive energy meter, and three elements 90° reactive energy meter .

Main functions

1.It can test various single and three phase electronic and mechanical meters,
2.It can automatically or manually test 1ph or 3ph meters': basic error, creeping teststarting test, standard deviation and etc,, the testing plan can be fixed by customers;
3.It can execute the influence test includes: voltage influence, frequency influence,harmonic influence, reverse phase sequence influence, unbalance voltage influencetest;
4.Support DLT-645 communication protocol, and can execute some tests formulti-functions energy meters;
5.More output terminals for more operations: RS232, RS485, extend l/0, EthernetUSB, wifi and etc.;
6.Output 2~63 harmonics
7.8 inch touchscreen and friendly operation system,
8.It can test 3 pcs meters maX.
Portable Meter Test System For AC Voltage Current Power Phase And Frequency Output

Send your message to this supplier
Send Now

Portable Meter Test System For AC Voltage Current Power Phase And Frequency Output

Ask Latest Price
Brand Name :
GENY
Model Number :
YC99T-3C/5C
Certification :
ISO, CE
Place of Origin :
CHINA
Payment Terms :
L/C, T/T, D/P
Supply Ability :
50/Year
Contact Supplier
Portable Meter Test System For AC Voltage Current Power Phase And Frequency Output
Portable Meter Test System For AC Voltage Current Power Phase And Frequency Output

Guangzhou GENY Electric Co., Ltd

Verified Supplier
2 Years
guangzhou
Since 1987
Business Type :
Manufacturer, Exporter, Seller
Total Annual :
2,000,000-10,000,000
Employee Number :
50~100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement