HS-6303E three-phase energy meter testing bench
SUIT FOR "CT &DC METER" & Single-phase/Three-phase meter
HS-6303E three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high-grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.
This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by customer.
This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.
This series of testing bench can test all kind of single phase energy meters, single phase multi-function meters, single phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.
CLASS | 0.02 | 0.05 | 0.1 |
Reference standard energy meter | HS-5300H 0.02 | HS-5300 0.05 | HS-5300 0.1 |
Output range | Voltage:3×30~300V Current:3×1mA~120A | Voltage:3×30~300V Current:3×10mA~120A(200A Option) | |
Output phase shift | 0~360°,resolution:0.01° | ||
Output frequency | 45~65Hz ,resolution:0.01Hz | ||
Waveform distortion | Both Voltage and current<0.5%( relative liner load) | ||
Voltage ¤t power stability | <0.02%/120s | <0.05%/120s | <0.1%/120s |
Output capacity | Voltage:300VA(6 stations) Current:250VA(120A) | Voltage:300VA(16 stations)current:900VA(120A) | |
Load characteristics | Resistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF) | ||
Starting up current output | Min.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5% | ||
sampling pulse input | ≤1kHz | ||
Communication testing | RS485/232/ infrared/carrier wave, support DL/T645-1997/2007,IEC1107 | ||
Number of energy meters to be tested | 6/16(standard),3-60 (optional) | ||
Environment condition | temperature:20℃±5℃;humility:<85% R.H. | ||
Power supply | AC220 ±10%,50/60Hz,AC120/240V(optional); |
Integration | stations | Number of rack | dimension:L×W×H | Fission | stations | Number of rack | dimension:L×W×H |
6 | 1 | 2000×800×1600 | 12 | 1 | 2000×700×1920 | ||
CUSTOM | 16 | 1 | 2200×700×1920 | ||||
12 | 1 | 2000×800×1920 | 24 | 2 | 2000×700×1920 | ||
16 | 1 | 2200×800×1920 | 32 | 2 | 2200×700×1920 | ||
24 | 2 | 2000×750×1920 | cabinet | 600×800×1920 |
Description | Range of application | |
HS-6303 | three-phase energy meter testing bench | Standard energy meter testing |
HS-6303B | three-phase multi-function energy meter testing bench | Multi-function energy meter testing |
HS-6303C | three-phase horizontal energy meter calibration bench | Energy meter error calibration |
HS-6303E | three-phase energy meter test bench with ICTS | 1P3W energy meter testing |
HS-6303F | three-phase intelligent energy meter testing bench | intelligent energy meter testing |
HS-6303G | three-phase energy meter (round meter) testing bench | Standard energy meter testing |
HS-6303M | three-phase din-rail energy meter testing bench | Multi-function energy meter testing |
HS-6303H | three-phase high precision energy meter testing bench | Energy meter error calibration |
Function item | HS-6303 | HS-6303B | HS-6303C | HS-6303E | HS-6303F | HS-6303G | HS-6303M | HS-6303H | |
Base testing functions | Base error | ● | ● | ● | ● | ● | ● | ● | ● |
Creep testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Starting up testing | ● | ● | ● | ● | ● | ● | ● | ● | |
standard deviation | ● | ● | ● | ● | ● | ● | ● | ● | |
Constant calibration | ● | ● | ● | ● | ● | ● | ● | ● | |
Counting error | ● | ● | ● | ● | ● | ● | ● | ● | |
Influencing testing | ● | ● | ● | ● | ● | ● | ● | ● | |
Multi-function testing | Daily timing error☆ | ● | 〇 | 〇 | ● | 〇 | |||
Period switching | ● | 〇 | ● | 〇 | |||||
Demand period error | ● | ● | |||||||
Demand display error | ● | ● | |||||||
Energy display error | ● | ● | |||||||
register checking | ● | ● | |||||||
GPS clock synchronization☆ | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
Communication testing☆ | ● | 〇 | 〇 | ● | 〇 | 〇 | 〇 |
For Item ☆ need special function parts
Type | HS-6303 | HS-6303B | HS-6303C | HS-6303E | HS-6303F | HS-6303G | HS-6303M | HS-6303H |
Standard energy meter | ● | ● | ● | ● | ● | ● | ● | ● |
power source | ● | ● | ● | ● | ● | ● | ● | ● |
error processing system | ● | ● | ● | ● | ● | ● | ● | ● |
multi-path pulse input | ● | 〇 | ● | ● | 〇 | 〇 | ||
Auto searching mark | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
auto short circuit | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
ICT | ● | |||||||
parallel communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
carrier communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | ||
IR communication | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
power consumption testing | 〇 | 〇 | ||||||
DC and even harmonic wave | 〇 | 〇 | ||||||
standard clock tester | ● | 〇 | 〇 | ● | 〇 | |||
GPS clock synchronization | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | |
collective turn over & optoelectronic sampling | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 | 〇 |
PRODUCTS DETAILS:
Standard Energy Meter Output Current: 4* 0-120A, one current circuit for neutral current Voltage: Up to 300V CT circuit accuracy 0.1 10 Meter Positions Split Type Close Link Test Interface with computer |
BACK OF TEST RACK.
REFERENCE METER(HS-5300)
SIGNAL SOURCE:(HS-6633)
QUICK CONNECTOR(Active & reactive pulse)
ISOLATED CURRENT TRANSFORMER(ICT)
Isolated Current Transformer Equipment:(HS-9503B) HS-9503B Isolated current inductance Accuracy class: 0.01 (COSφ=0.5C-1-0.5L,0.1~120A) Primary current: 3×0.025mA~120A secondary current: 3×0.025mA~120A Output power: 60VA (MAX,120A) |
CALIBRATION CERTIFICATION
As customer's requirement,we can supply 3rd part calibration certification. with CNAS mark.