HS-1013 DC Harmonic Tester
For testing DC Harmonic.
AS the IEC62053-21 Ponit 8.2.3 . requirement:
Use our HS-1016 DC & Even Harmonic Tester together with our HS-6103 & HS-6303 Single /Three Phase Energy Meter Test Bench can do this test function.
Voltage get from bench position.(Must careful,when you on the current &voltage,don’t touch the bench pins.)
If you scanning head connect at Position 3.then when you test with software,choose the position 3.
If your meter is “220V,10(100)A” Then you want to 220V,10A. Then choose” 100%U,100%Ib”.
40A.(400%Ib)
Then click “Half Wave= DC harmonic”
It will start to test EUT meter’s error.
-----------------------------------------------------------------------------------------------------------------------------
Overview
HS-1016 DC and Even Harmonic Tester is used for GB/T17215.321-2008 DC and Harmonic Testing.Suitable for the DC and even harmonic testing requirement of all calibration center,power calibration department and energy meter manufacturer.
Function Advantage:
Technical Specification
Test Range | 0.1~100A |
Construction & Dimenstion | Adopt standard 4U,19”carte |
Power supply | AC 220V±10%, 50/60Hz |
Operating environment | Temperature:0℃~40℃; Humidity:<85%R.H. |