HS-6121 withstand voltage test bench for single-phase watt-hour meter
is new-generation withstand voltage test bench for watt-hour meters which is introduced to the market by Shengdi Electrical in a powerful and sensational way to go with the market demand. That test bench is designed with both combinable and splittable high-voltage outputting and testing assemblies and the test process can be performed both manually and automatically. With meet well current market demand for watt-hour meter’s withstand voltage test. So it is an ideal withstand voltage test bench for single-phase multi-station watt-hour meter.
Technical Parameters
WITHSTAND VOLTAGE TESTER PARAMETERS
1.Input voltage: AC 220V±10%
2.Output voltage:0KV-5KV AC/50Hz, Accuracy: ±5%
3.Output capacity:≥500VA
4.Current leakage: Maximum current leakage:100mA
5.Voltage test operation modes: both manually and automatically
6.Time control: 0~99s optional, Accuracy: ±5%
TEST BENCH PARAMETERS
1.Number of meters to be hung: 10(standard),0-60 single-phase watt-hour meters optional
2.Max. power consumption:500VA
3.Current leakage per meter station:5mA±5%
4.Output waveform distortion:<5%
5.Insulation resistance of voltage loop, current loop, and all other circuits to ground: all larger than 10MΩ
6.Combined error of voltage output: not larger than±2%
7.Operating environment: Temperature: 0~45°,relative humidity: not larger than 85%
8.External form of test bench(PIC.)
Meter hanger:2200×600×1920mm(48 meter stations), test bench:600×600×1200mm
Standard 12 & 24 Positions Dimensions:
Integration | Fission | ||||
Stations | Rack | L*W*H(mm) | Stations | Rack | L*W*H(mm) |
12 | 1 | 2200×750×1600 | 12 | 1 | 2200×750×1600 |
24 | 1 | 2200×750×1920 | 24 | 1 | 2200×750×1920 |
Cabinet | 600×800×1650 |