NEW Type 2P 5/15A 10/30A 30/60A Adjustable Earth Leakage Circuit Breaker PG Adjustable trip circuit breaker
Adjustable RCBO Breaker Africa Type 10-15-20-25-30a 250V/440V,différentiel 500 ma instantané, Triple Pole Rcbo
Specifictions
CE,CERTIFICATED
. Quality guarantees 2 years
. Professional manufacture for more than 20 years
We can supply all kinds of MCCB ODM and OEM orders are welcome.
TYPE | BHG(PG) | |
Poles | 2p | 4p |
Rated Voltage (V) | 230V | 440V |
Rated Current (A) | 5~15A(5.10.15A) 15~45A(15.30.45A) | 10~30A(10.15.20.25.30A) 30~60A(30.45.60A) |
Leakage operating current(mA) | 300mA | 500mA |
Leakage non-operating current(mA) | 150mA | 250 |
Standard | NFC61450, NFC62411 |
-
Electrical characteristics
- earth leakage break time: < 0.2 s for 1 In , < 0.1 s for 2 In
- earth leakage tripping: 300 mA, 500 mA or 650 mA
- operating temperature: - 5 ° C to + 60 ° C
- voltage drop: 1 pole + neutral < 0.9 V
- insulation resistance: > 2 M
- dielectric withstand
- 2 kV AC for 1 minute
- 4 kV between poles and frame
- tripping curve: C type & D type
- operation in all positions
- ON/OFF control by push-button
- rating easily changed
- lead-sealable terminal shields
- captive terminal screws
- pivoting terminals
- copper cables up to 35 mm²
- neutral identified in blue
NEW Type 2P 5/15A 10/30A 30/60A Adjustable Earth Leakage Circuit Breaker PG
Normal operating conditions and installation conditions
■ Altitude is not more than 2000 meters;
■ Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃;
■ The location of the air relative humidity in the highest temperature + 40℃ for not more than 50%; For example, + 20℃ for 90% . And consider the temperature changes in product on the surface of the gel;
■ Installation conditions: installed in the place without impact vibration and invasion of rain and snow; no explosion hazard in the medium, and medium without enough to corrode the metal and destruction of gas and electric insulation dust;
■ Pollution degree: 2;
■ Installation category: Ⅲ;
■ Electromagnetic environment is Environment B;
■ The external magnetic field of installation site in any direction should not exceed 5 times of the geomagnetic field;
■ TH35-7.5 rail installation, installed in the distribution box, power distribution cabinet or box;
■ The installation adopts vertical installation, The inclination of the mounting plane to the vertical plane should not exceed ± 5 °, handle-up means power-on.

OUR FACTORY


NEW Type 2P 5/15A 10/30A 30/60A Adjustable Earth Leakage Circuit Breaker PG
Our Services
(1) Warranty ( 24 months warranty )
1. The warranty starts from the delivery date from our factory;
2. During the warranty, any defective product will get repaired or replaced for free ;
3. It is beyond the warranty as the products breaked by the violence , the carelessness or repaired , altered without authorization.
(2) Lead Time
1. Sample orders will be delivered from our factory within 7 working days.
2. General orders will be delivered from our factory within 7-15 working days.
3. Bulk orders will be delivered from our factory within 25 working days at most
(3) Shippment
1. By EMS, DHL, FedEx, TNT, UPS or other express.
2. By our forwarding agent (by air or by sea).
3. By your own forwarding agent.
4. By domestic forwarding agents to any city in China