This is the Highbay PIR sensor,suitable for UFO high application with UL certificate, it can be control by remote, there are some actual functions, and it has easy connection way.
Model NO. | HD07VR-PH-1 | |
PIR INFORMATION | Infrared Wavelength | 5-14um |
Output Signal Peak | ≥3500mV | |
Installation Height | 12m/39ft Max. | |
Detection Distance | ≥3m/9ft | |
Warranty | 3 Years | |
SENSOR PARAMETER | Detection Area | 25%/50%/75%/100% |
Holdtime | 5s/30s/1min/3min/5min/10min/20min/30min | |
Daylight Threshold | Disable/ 2lux/ 10lux/ 30lux/ 50lux/ 80lux/ 120lux | |
Standby Dimming Level | 10%/20%/30%/50% | |
Standby Period | 0s/10s/30s/1min/5min/10min/30min/60min+∞ | |
Dusk/Dawn Sensing/ Photocell | Daylight threshold as 30lux/ 50lux/ 80lux/ 120lux Standby period as +∞ ; Standby dimming level as 10%/20%/30% | |
Default Program | Detection Area - 100% Holdtime - 5S Daylight Threshold - disable Standby Period - 0S Standby Dimming Level - 10% | |
Control | Standard Partner HD05R, the LCD screen display remote (purchase seperately) | |
INPUT | Input Range | 12VDC |
Voltage Range | 10-15VDC | |
Current | ≥30mA | |
OUTPUT | Signal | DIM 0-10V |
Connection | 12VDC input/ Black&White wire; DIM+/ Purple wire; DIM-/ Pink wire | |
Stand-by Power | <30mA Power Consumption | |
ENVIRONMENT | Working Temp | -20°C~+60°C |
Storage Temp | -40℃~+80℃ Humidity: 85%(non-condensation) | |
CERTIFICATE & STANDARDS | Certification | UL (E529048) |
Environmental Requirements | In accordance with CE ROHS | |
IP Rating | IP20 | |
PACKAGE | Silk-Printing | Lasering |
Packing Description | 1pcs/white neutral box | |
Qty/ctn(pcs) | 120 | |
Net Weight/pcs (kg) | 0.05 | |
Gross Weight/CTN (kg) | 6.6 | |
Carton Size (cm) | 40*30*25 |
1. Suitable for indoor application, half/completely outdoor environment conditions might trigger the sensor.
2. Suitable for ceiling mount installation, adjust sensitivity properly if it's installed on side-wall because it gets more sensitive.
3. PIR sensor can't be placed inside any material, fresnel lens must completely exposed in air.
4. Fresnel lens of the PIR sensor must be lower than light fixture.
5. Not suitable environment if there's sudden changed temperature of airflow for PIR sensor.
6. Not suitable environment if there's shelves blocking between the sensor and presence area.
7. Detection area options may NOT working obviously because it works depends on fresnel lens, it's physically defined.
8. Detection distance performance works better when moving parallelly than moving towards to the sensor.
9. Daylight testing delivered in bright day without shadow or specially designed lampshade or lens.
10. Dimming performance differs when connected to different drivers; If the driver can't completely turn OFF, sensor can't either.
11. Input power voltage must be stable with float less than 10%.
12. The first time powered ON sensor, light will be ON 100% for about 45S then dims to standby level or OFF.
13. Distance detection is delivered by testing person about 165cm in open area as reference, the result differs by size and speed of moving objects, mountng height and real-life situation.