Tri Proof Light 0.3mW Microwave Movement Sensor 8 DIP Switch Control
8 DIP Switch Control 20-60V Nominal Voltage DC Input Motion Sensor
Setting of DC sensor:
| |
Detection area(1) | In this area,movement will be detected and able to trigger the sensor.100% detection area is also known as the strong sensitvity. |
Hold-time(2,3) | The period of light keeping 100% brightness after moving objects leave the detection area. |
Daylight threshold(4,5) | Definition of the ambient brightness;only when the ambient brightness is lower than the preset specific lux amount, the sensor will work; when it's preset as "disable",the sensor works everytime it detects motion regardless the ambient brightness. |
Stand-by period(6,7) | The period of light keeping low output before it's completely switched off.When it's preset as"∞“, the light always keep at low output if no movement in the detection area and doesn't turn off. |
Stand-by dimming level(8) | The definition of low output in the standby period. |
Wiring diagarm of DC sensor:
Control mode | ON/OFF /dimming(PWM) |
Output | Dimming |
Stand-by power | ≤0.5W |
Microwave frequency | 5.8GHz±75MHz |
Microwave power | <0.3mW |
Operating voltage | 20-60VDC |
Detection coverage of DC sensor:
Mounting height | 2.5-4m/8.2-13.12ft (ceiling mounted) |
Detection range | ø4-10m/13.12-32.8ft (ceiling mounted) |
Detection angle | 30°-150°(Without glass) |
Motion detection | 0.5~1.5m/s |
Features of DC sensor:
1. 8 DIP switch keys to set hold time, stand-by dimming level, stand-by period
2. Particularly suitable for price sensitive luminaries
3. With DC operation voltage from LED driver, no need extra power from line
4. 2.5-4m mounting height for being applied in parking lot, lowbay warehouse
5. 39.9mm width for being applied to tri-proof light perfectly
6. Stand-by power less than and equal to 0.5W
7. φ5.5mm rod antenna, need a small hole to expose the antenna, no shadow, no affection on the light beads array