Specifications
Brand Name :
MICH
Model Number :
PSMIHECU
Certification :
ISO9001
Place of Origin :
China
MOQ :
1 meter
Price :
USD0.5-USD5 per meter
Payment Terms :
L/C, T/T
Supply Ability :
20 million meters
Delivery Time :
in one month
Packaging Details :
plywood crates
Property :
Physical Stable
Function :
Heating or Heat Trace
Application :
Construction
Diameter :
up to project request
Cable Length :
in Meter
Power :
in Watt
Voltage :
in Volt
Unit Weight :
Up to 184 kg/km
Description

Physical Stability Mineral Insulated Heating Element for Construction Use

Physical Stability Mineral Insulated Heating Element for Construction Use is technical solutions for heating on the construction field with the detailed applications as below:


1. Heating of cement fast drying, pre-drying and heating of firebrick;
2. Floor heating for residential and industrial buildings;
3. Snow and ice melting for decreasing load on roof;
4. Heating for ice blocking prevention for gutter and downpipe;

5. Others

Mineral Insulated Heating Element for Chemical Industry Heating or Heat Trace is to be designed based on selection of mineral insulated heating cable which is prefabricated in the manufacturer's workshop into a heating element that can be directly connected to the power supply. It is usually composed of heating cables, cold and hot joints, cold end cables, terminals, tail ends and lead wires, etc. There are the following types can be selected from including type A, Type B, Type C, Type D, Type E, Type F and Type G structures. Among them, Type A, B and C are only suitable for single-core heating cable, while type D, E, F and G are only suitable for double-core heating cable.

Mineral Insulated Heating Elements For Construction Use

Common structure of the heating cable for the heating element is of single core and two core, while the customization can be according to clients’ needs to design and provide MI heating cable of three core or more.

Mineral Insulated Heating Elements For Construction Use

Specification

Heating cable instruction code

MI AL-B 16K6560/60/2520/220/E1

No. 1 2 3 4 5 6 7

No. Instruction
1 Sheath material 825 alloy
2 structure of cable components shown in table 1
3 cable codes shown in table 2, 3 and 4
4 length of heating cable In meter
5 Heating cable power In Watt
6 heating cable voltage In Volt
7 heating cable voltage See table 5

Cable Code

1 6 K 6560

No. 1 2 3 4

Serial NO. Instruction
1 core number 1 or 2
2 Voltage grade 3=300V, 6=600V
3 conductor materials K,N,C
4 cold resistance ×1000 6560=6.56Ω/m×1000

Table 2 Heating Cable Specification (600V Single Core)

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
16C2.1 6.8 0.0021 130 220.7
16C3.4 5.9 0.0034 173 162.5
16C5.3 5.3 0.0053 214 125.6
16C8.5 4.8 0.0085 261 101.6
16C13 4.3 0.013 325 79.1
16C21 4.0 0.021 376 65.8
16K40 5.8 0.04 179 157.1
16K50 5.4 0.05 206 135.6
16K60 5.2 0.06 222 122.8
16K80 4.8 0.08 261 101.2
16K100 4.7 0.1 200 99.5
16K120 4.5 0.12 200 88.8
16K160 6.5 0.16 200 202.2
16K200 5.9 0.2 200 166.5
16K250 5.3 0.25 215 131.7
16K400 4.7 0.4 280 96.7
16K500 4.5 0.5 300 87.7
16N630 4.3 0.63 185 82.2
16N1000 3.9 1.0 230 62.8
16N1600 3.6 1.6 270 52.4
16N2500 3.4 2.5 300 45.6
16N2800 3.4 2.8 300 45.2
16N3300 3.4 3.3 300 44.7
16N4000 3.2 4.0 350 38.1
16N5200 3.2 5.2 350 37.7
16N6300 3.2 6.3 350 38.4
16N10000 3.2 10 350 38.9

Table 3 Heating Cable Specification (600V Double Cores)

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
26K8.4 11.8 0.0084 43 632.9
26K13.4 9.8 0.0134 63 431.5
26K21 8.8 0.021 78 339.0
26K34 8.0 0.034 94 273.7
26K54 7.1 0.054 119 212.4
26K85 6.4 0.085 147 170.2
26K130 6.0 0.13 167 147.8
26K180 7.9 0.18 96 271.9
26K260 7.4 0.26 110 234.2
26K360 6.8 0.36 130 195.5
26K500 6.4 0.5 100 171.2
26K650 5.9 0.65 100 144.8
26K1000 5.7 1.0 100 133.3
26K1300 6.2 1.3 100 160.6
26K2000 5.8 2.0 100 139.1
26K3300 5.4 3.3 100 118.8
26N4600 5.8 4.6 100 138.3
26N8000 5.4 8.0 100 118.6
26N13000 5.0 13.0 100 100.8
26N27000 4.8 27.0 100 92.1
26N40000 4.6 40.0 100 84.4
26N60000 4.4 60.0 100 77.1
26N72000 4.2 72.0 100 70.2

Table 4 Heating Cable Specification (300V Double Cores)

Cable Code Diameter Nominal resistance at +20 Maximum manufacturing length Unit weight
mm Ω/m m kg/km
23K210 5.2 0.21 222 117.9
23K300 4.8 0.3 261 98.9
23K400 4.8 0.4 261 97.2
23K480 4.8 0.48 261 96.0
23K650 4.6 0.65 284 87.3
23K1000 4.1 1.0 100 68.9
23K1300 3.8 1.3 100 58.9
23K2000 5.0 2.0 100 104.7
23K2400 4.8 2.4 100 95.7
23K3000 4.6 3.0 100 87.3
23N4600 4.8 4.6 100 96.3
23N7500 4.6 7.5 100 86.9
23N11200 4.4 11.2 100 78.7
23N14000 4.2 14.0 100 71.6
23N18000 3.6 18.0 100 52.6
23N26000 3.6 26.0 100 52.2
23N40000 3.4 40.0 100 46.4
23N50000 4.0 50.0 100 63.8
23N60000 3.6 60.0 100 51.7
23N72000 3.4 72.0 100 46.1

Note: the resistance value of 2-core cable in the above table is the measured value after the ends are twisted (i.e., single-core resistance X2);

For the use of 660V voltage occasions, please contact our company professionals.

Table 5 terminal specifications

Model: A, D, E Model: B
Maximum Voltage(V) Maximum Current (A) Terminal Specification Maximum Current (A) Terminal Specification
600 15 E2 20 E1
600 20 E2 25 E2
600 30 E3 40 E2
600 50 E3 70 E2
600 70 E3 100 E3

Note 1: E1 means 1/2 "NPT;E2 means 3/4 "NPT;E3 represents 1 "NPT (taper thread);Additional connection thread requirements are available.

Note 2: the length of cold end cable with standard configuration is 2 meters. If you increase or decrease of length required, please contact our professional personnel.

Anticorrosive specification

Material
Sulfate good
Hydrochloric acid good
Hydrofluoric acid good
Phosphate good
Carbonate good
Organic acid good
Alkali metal good
Sea water good
Chloride good

Explosion-proof instructions

MIAL series heating cable with explosion-proof terminal, can be used in potential explosive environment. Authenticated by the Chinese CQST, in accordance with Chinese GB3836 explosion-proof electrical standards, they can be applicable to A, B, C (C1D2) level of explosion-proof electrical equipment.

Send your message to this supplier
Send Now

Mineral Insulated Heating Elements For Construction Use

Ask Latest Price
Brand Name :
MICH
Model Number :
PSMIHECU
Certification :
ISO9001
Place of Origin :
China
MOQ :
1 meter
Price :
USD0.5-USD5 per meter
Contact Supplier
Mineral Insulated Heating Elements For Construction Use
Mineral Insulated Heating Elements For Construction Use

Pasia Industries Ltd

Active Member
5 Years
zhejiang
Since 2008
Business Type :
Manufacturer
Employee Number :
150~200
Certification Level :
Active Member
Contact Supplier
Submit Requirement