Description of 4000LPH for bottle filling drinking pure water purifying machine
Technical descriptions of 4000LPH RO water treatment machine:
The water treatment system is divided into 4 parts: Pre-treatment, RO unit, sterilization parts and matching parts. RO is the core of the system. This machine can purify your raw water to pure drinking water by the capacity 4000liters per hour.
The purified water can be used
1. For residents to drink and boil water.
2. For commercial bottles of purified water.
3. For agricultural irrigation and drinking water.
4. Electronic cost accounting industry
This is the Silica sand filter/quartz sand, Actived carbon filter, Sodium ion exchanger / water softner with salt tank and precision filter/cartridge filter
Equipment list of 4000LPH RO water pruification machine:
Items | Name of machine | Model | Size(mm) | Qty. |
1.1 | Raw water pump | CHL16-20 | / | 1set |
1.2 | Quartz sand filter | SUS600 | φ600*2500 | 1set |
1.3 | Active carbon filter | SUS600 | φ600*2500 | 1set |
1.4 | Cartridge filter | SUS350 | φ350*1600 | 1set |
1.5 | RO unit (anti-scale dosing device included) | RO-4000 | 2700*600*1500 | 1set |
1.6 | Connection pipes&valves | UPVC | / | 1suit |
1.7 | Ozone sterilizer | T10G | 360*260*610 | 1set |
1.7.1 | Injector | 32235 | / | 1set |
Option | ||||
1.8 | Sodium ion exchanger | SUS600 | φ600*2500 | 1set |
1.9 | Sodium ion rebirth device | 200L | / | 1set |
RO membrane is the key part of whole RO, it will decide the system workable or not. The water passing RO can remove bacterial, organic substance and microorganism.
RO performs a separation without a phase change. Thus, the energy requirements are low.RO systems are compact, and space requirements are less than with other desalting systems, e.g. distillation. Water recovery rate is high, small in dimension, high automation.
Whole SUS304 rack, automation part apply AC contactor control, apply flow meter, pressure gauge and auto flush electrical magnetic valve, etc.
Protect device:Low pressure and high pressure protect switch is set before water entry and after water discharge. Booster pump and system will stop when water supply is not enough. Make cut off on booster pump when there is too much discharge pressure to avoid system running under pressure exceeding status.
This is the UV sterilizer for 4000LPH RO water purifying machine:
Configuration of the RO main part:
ITEM | Unit | RO-4000 | Brand | |
Flow rate | L/H | ≥8000 | ||
Recovery rate | % | 50-75 | ||
Design pressure | MPA | 0.8-4.5 | ||
Dimensions | MM | 2700*600*1500 | ||
High pressure pump | SET | CDLF8-12 4KW *1 | NANFANG | |
Membrane housing material | PCS | FRP(8040-1)*4 | Rework | |
8040 Membrane | PCS | Polyamide material*4 | HYDECANME | |
Volume of anti-scale dosing device | Litre | PE-200L*1 | ||
Water flowmeter for salinity water | PCS | 1 | ||
Water flowmeter for purified water | PCS | 1 | ||
Low pressure protector for high pressure pump | PCS | 1 | ||
High pressure protector for high pressure pump | PCS | 1 | ||
Pressure gauge for salinity water | PCS | 1 | ||
Pressure gauge for purified water | PCS | 1 | ||
Conductivity meter | PCS | 1 | ||
PLC | PCS | 1 | Mitsubishi | |
Program controller (errors alarm) | PCS | 1 | ||
Air switch | Suit | 1 | Schneider | |
Contactor | Suit | 1 | Schneider | |
Relay | Suit | 1 | Schneider |