LIRUISI Uninterruptible Power Supply Power Frequency Machine Series HP200KVA
Product Presentation:
Cost-Effective Choice: The UPS uninterruptible power supply system connected to the power frequency machine series removes the necessity for supplementary equipment. It can be directly connected to the power frequency machine, ensuring remarkable convenience and cost-effectiveness.
Swift Recharging: The UPS uninterruptible power supply system linked to the power frequency machine series facilitates rapid recharging via direct connection to the primary power source or battery. This culminates in a shorter recharging period and expedited power restoration.
Functional Process:
The power frequency machine functions using a three-in, three-out, double-conversion online method, ensuring consistent and reliable power supply.
Special Features of the Product:
Incorporates advanced IGBT high-frequency pulse width modulation (PWM) technology to mitigate system noise and minimize power loss. This pledges customers a top-notch voltage output and utmost efficiency across diverse operational conditions. Through dual conversion and a pure online sine wave output, the system generates a pure sine wave power supply with minimal distortion in both mains and battery modes. This attribute guarantees optimal power support for the user's load equipment.
Product parameters:
HP10KVA-HP400KVA [Power frequency tower three-in, three-out UPS system] | |
Model | HP200KVA |
Nominal capacity (KW) | 160 |
Single-phase input maximum current (A) | 379 |
Working method and principle | In-line power supply, static bypass switch (non-stop switching), double conversion technology, the output power supply is completely isolated |
Input power factor | 0.8/0.9 (12 pulses)/0.95 (with active filter) |
Phase number | Three-phase + N + G |
Nominal voltage | 380VAC±25% |
Nominal frequency | 50HZ±10%,60HZ±10% |
voltage harmonic distortion | <5% |
soft start | 0~100% 5 sec |
HP10KVA-HP400KVA [Power frequency tower three-in, three-out UPS system] battery | |
Maximum discharge current (A) | 546 |
Number of batteries per group | 12V type 32 sections or 2V type 192 sections |
Nominal battery voltage | 384VDC(348V-384V可设);160~400KVA:384/396VDC |
float voltage | 432VDC |
charging current | 6~ 30A (adjustable) |
HP10KVA-HP400KVA [Power frequency tower three-in, three-out UPS system] bypass | |
Phase number | Three-phase + N + G |
Nominal voltage | 380VAC±15% |
Nominal frequency | 50HZ±5%;60HZ±5% |
Transition time | 0ms |
HP10KVA-HP400KVA [Power frequency tower three-in, three-out UPS system] overall system | |
Communication interface | RS232, RS485, Dry Contacts, Smart Slots |
Operating temperature | 0~40℃ |
Relative humidity (non-condensing) | 0%~90% |
Operating height (max) | < 1000 meters (1% decrease in power for each additional 100 meters, up to 4000 meters) |
Cooling method | forced ventilation |
Protection class | IP20 |
Box color | White or black |
Easy to maintain | Front/top/side |