LIRUISI Rack Mounted Computer Room Precision Air Conditioner CDA Series 0008
Product introduction:
LIRUISI's CDA series rack air conditioner is a cabinet-level temperature control product designed for single-row systems in high-heat density data centers, which is placed close to the heat source on the cabinet rack.It can accurately handle the high sensible heat generated by the servers in the cabinet, effectively prevent the generation of local hot spots, and help the continuous development of green data centers.
Rack-mounted machine room precision air conditioner has the following advantages:
1. Complete functions: The precision air conditioner in the rack-mounted computer room has a series of functions such as precision temperature control and humidity control, which can be automatically adjusted in different environments, such as moisture-proof, defrosting, deodorization, etc. 2. Easy maintenance: The maintenance of precision air conditioners in rack-mounted computer rooms is relatively simple, and the maintenance work is also relatively convenient.
Product parameters:
LIRUISI 【CAD Series Rack Cooling Module Refrigeration System】 | LIRUISI CAD Series Rack Mounted Cooling Module Refrigeration System [Inner Unit Size and Weight] | ||
ndoor unit model | CDA0013 | Unit width (mm) | 444 |
Unit depth (mm) | 400 | Unit depth (mm) | 395 |
Main power supply | 220/1ph~50HZ | Unit height (mm) | 352 |
Air supply method | Three side air supply | Weight (kg) | 36 |
CDA series rack cooling module refrigeration system unit【Performance parameters】 | CDA series rack mounted cooling module refrigeration system [external unit performance parameters] | ||
Cooling capacity (kW) | 8 | Outdoor unit model | CDT0010SP |
apparent cooling capacity | 8 | Unit width (mm) | 1045 |
Maximum working current of the unit A | 20 | Unit depth (mm) | 431 |
Number of compressors | 1 | Unit height (mm) | 760 |
Fan form | EC fan | Weight (kg) | 60 |
Number of fans | 2 | CDA series rack mounted cooling module refrigeration system【Recommended power distribution specifications】 | |
Circulating air volume (m3/h) | 1650 | Recommended open | 25 |
Heating capacity (kw) | 1 | Indoor unit power cord (mm2) | 3*4 |
Humidification capacity (kg/h) | / | Outdoor unit power cord (mm2) | 3*2.5 |
CDA series rack mounted cooling module refrigeration system [connection pipe size specifications] | |||
liquid tube | 12.7 | ||
trachea | 19.05 | ||
Humidification inlet pipe | OD20*G3/4 | ||
Unit water pump drain pipe | PU tube ID5 * OD8 | ||
Unit natural drain pipe | Silicone hose ID10 * OD14 |