LIRUISI-ROW Series Micromodule Room Dedicated Single-Row System Black
Product Introduction:
【 LIRUISI-ROW series integrated single-row data center adopts modular design, which can meet the flexible composition of 1 (1-8) single-cabinet micro-module, directly coupling and splicing between cabinets, forming a double air duct closure on the hot and cold side, integrating the power supply and distribution system, air conditioning system, cabinet system, closed channel system, monitoring system and wiring system, and configuring various environmental data sampling sensors, bringing safe, reliable, compact and convenient computer room deployment experience to unused users.
Application scenarios:
smart finance, smart education, smart healthcare, smart government, smart transportation, smart security, can be applied to dust and wet environments. There is no dedicated computer room space.
Product Features:
2m standard cabinet with larger 42U capacity;Support 1 tow (1-8) cabinet consolidation;There is no need to add additional air duct components, and the cabinets are directly decoupled and assembled to form a "hot and cold dual-channel double-closed" system;Can be installed on cement floor, suitable for five high-floor machine rooms;Ultra-wide voltage range: 138~485V;Ultra-wide temperature range: 40~55°C;
Product parameters:
【LIRUISI-ROW】Technical parameters of intelligent micro-module data center system | |
Product model | LPSRITS-ROW |
Performance parameters | |
Total number of counters | 2~ 9 cabinets |
Reliability, channel isolation | IP20, hot and cold dual channel isolation |
PUE value | Less than or equal to 1.2 |
Installation requirements | ≥2.3m, support direct installation of cement floor/raised floor (civil buildings can be deployed, no independent room required) |
cabinet | |
Dimensions | 600*1400*2000 |
Total IT load capacity | Less than or equal to 36KW |
temperature control | |
Cooling capacity | Cooling capacity Rack air conditioner: 3.5~ 12.5 |
emergency refrigeration | Emergency fan |
power supply and distribution | |
Input power system | 220V, 50HZ or 380V, 50HZ, support dual inputs |
UPS Capacity Rack UPS | Rack UPS: 3-90 |
monitor | |
Monitoring interface | Near-end 10-inch touch screen, web page, client side |
Equipment & Environmental Monitoring | Air conditioning, power distribution, UPS, temperature and humidity, water leakage detection, smoke detection, door status detection, fire linkage |
Intelligent monitoring | Battery monitoring, video surveillance, electronic access control, intelligent linkage of external environment refrigeration, multi-site centralized management |
fire protection | |
Rack Fire Protection | Heptafluoropropane gas fire protection (optional) |
fire extinguishing agent | FM200/(optional Novec1230N), 0U bit mounted |
Trigger method | Fire detection tube (standard) / electronically controlled trigger / third-party fire system trigger / emergency manual button trigger |
Note 1: Reis provides customized phone service, the above configuration can be customized and detailed design according to the existing layout, facilities, and needs of the computer room |