Facial 980nm spider vein removal laser vascular removal machine medical devices
Features of our spider vein removal machine?
1. No bleeding, non-invasive,Newest laser technology for vascular removal and spider veins remvoval,
compared high frequency RBS therapy ;
2. 1-30W adjustable energy to satisfy different requirements.
3. less side effects: no burning, redness or scar.
4. Fast results : Only one or two treatments are requied.
5. Accurate treatment: energy is well focused onto 0.2-0.5mm spot .
6. Portable and smart design is covenient to do treatment.
Technological Theory
The target substance of vascular disease treatment is oxyhemoglobin in red blood cell in blood vessel. Wavelength affects laser’s depth of penetration. Under 1200nm, the longer the wavelength, the deeper laser can penetrate. Thus, laser wavelength is usually longer in vascular disease treatment so as to give consideration to target tissues’ selective absorption and penetrability. Besides, laser penetrates the epidermis melanin barrier and reaches targeted blood vessels. Short wavelength laser light will be competitively absorbed by epidermis melanin, which will cause epidermis injury and form cicatrix. 980nm Diode 980nm Laser Therapy system takes advantage of 980nm wavelength laser, penetrating epidermis and reaching blood vessels. Based on selective photothermolysis theory, oxyhemoglobin absorbs laser energy and produces thermal energy and spreads to vascular endothelial cells through conduction mechanism. In consequence, blood vessel wall is damaged and facial vascular will be treated.
The major targeted chromophore in facial vascular treatment is oxyhemoglobin that existing in red blood cell in vessels. According to the curve of laser absorption by targeted substance (right picture), oxyhemoglobin shows a much higher absorption interval in 900nm-1000nm. Thus 980nm semi-conductor laser has the ideal treatment effects for facial vascular removal.
Touch Screen
This device adopts 8 inch touch screen, which is the main interface for human-machine operation. All parameters setting, system control or equipment status can be realized through this screen.
Sharp objects are not allowed touch the surface of screen to avoid being scratched. Various kinds of liquids are not allowed to splash the touch screen to avoid damage.
Key Switch
Key switch controls on and off of the system. When it is in the position of ―O‖, the system is inactive state.
Two keys are randomly equipped with the Device. Only when the key switch is in the position of ―O‖, the key can be pulled out. When the key switch is in the position of ―|‖, the system of the Device will be launched and touch screen will display the main interface.
Keys for the switch should be kept and managed by personnel with professional trainings.
Technical Parameters
Laser Type | Diode laser |
Laser Wavelength | 980nm |
Laser Classification | Class 4 |
Electric Safety Classification | Type B ClassⅠ |
Laser Model | Pulser |
Laser Power | 16W Max. or 10W Max. |
Laser Energy | 0.1-11.4J or 0.1-6.6J |
Pulse Width | 10-650ms |
Pulse Frequency | 1Hz-10Hz |
Spot Size | φ0.2mm |
Beam Delivery | Fiber of 200μm, SMA 905 connector |
LCD screen | 8 inch |
Aiming Beam | 650 nm, <5mW |
Power supply | 110-240VAC,50-60Hz, 200VA |
Fuse Protector | F3A,250VAC |
Dimensions (Length ×Width ×Height) | 325mm×470mm×230mm |
Net Weight | 8Kg |