UVOZ-3000 Ozone Detector
UVOZ-3300C Ozone Concentration Analyzer is designed and manufactured in accordance with Lambert-Beer law, GB/T37397-2019 Ozone Calibration Analyzer, HJ 590-2010 Determination of Ozone in Ambient Air - Ultraviolet Photometry, GB/T37894-2019 Technical Requirements for Ozone Generators for Water Treatment, and the testing and calibration methods. The current ozone concentration value is calculated by measuring the change of light signal intensity before and after ozone absorption of UV light.
Intelligent Compensation: Built-in temperature and pressure compensation with display and automatic compensation of light source.
Operation mode: users can choose manual calibration and automatic calibration according to the operation status, and the time of automatic calibration can be set.
Display unit: g/Nm3, mg/NL, WT% can be customized optional.
Data display: color touch screen, high concentration range setting into the gas mass flow, real-time display output (optional).
Output function: 4-20mA, RS485 communication, two groups of alarm point output, electronic flow meter input.
Standard configuration: anticorrosive flow meter, ozone tail gas destroyer, ozone inlet filter.
model | UVOZ-3300C |
Measure the range | 0-300g/Nm3 |
Optional range | 0-400g/Nm3;0-200g/Nm3;0-100g/Nm3;0-50g/Nm3;0-10000ppm; |
Light source life | About 30,000-50,000 hours; |
Sampling method | Positive pressure sampling, negative pressure sampling (optional); |
Display interface | 4.3-inch touch screen operation interface; |
Content interface | Ozone concentration, temperature, pressure; (yield calculation and data recording can be customized) |
additional function | Temperature compensation, pressure compensation; |
Display unit | Option of g / Nm 3, mg / NL,% WT; |
display resolution | 0.01g/Nm3; |
gas-flow rate | 0.5L±0.2L/min; |
input pressure | <0.1MPa; |
Concentration error | ≤0.5%FS; |
linear error | ≤0.5%FS; |
precision | ≤±3% |
zero drift | <±0.3%.FS; |
reaction time | Signal 0.03 seconds, display 0.3 seconds; |
ambient temperature | -20~50℃ |
Pipe interface mode | Quick twist (stainless steel); |
Tandem sample caliber | Φ 8 (8mm * 6mm) (optional); |
Bypass sampling caliber | Φ6(6mm*4mm); |
communication mode | RS-485; |
Output method | 4-20 mA (active); |
Following the electrical signal | High alarm point following the electrical signal, low alarm point following the electrical signal; |
source | AC 110-220V; |
size | 133mm (height) 482mm (width) 300mm (deep), 19-inch 3U chassis; (Note 1 mg/L = 1 g/m3 = 467 PPM); |
Free warranty | 24 months (host sensor); |
Ozone generator users include manufacturers, the municipal water sector, the industrial wastewater sector, the fine chemical sector, the food and drinking water sector, the space disinfection sector, the swimming pool disinfection sector, the flavor synthesis sector, and other industries.