Size | 4.33 x 2.36 x 1.10 in (110 x 60 x 28 mm) |
Weight | 8 oz (230 g) |
Sensor | Standard LEL (Pellistor), O2-LF (Pb-free), CO and H2S |
Alternatives CH4 (NDIR), O2 (Galvanic), SO2 and HCN | |
Replaceable but not interchangeable | |
Battery | Rechargeable Li-ion pack: ≥ 24 hours (with Pellistor) or extended run time (with NDIR) |
Direct Readout | Real-time reading of gas concentration |
Visual compliance indicator | |
Battery status | |
STEL, TWA, peak and minimum values | |
Display | Segment LCD, 1.75 x 1.25 in (44 x 32 mm) with LED backlight for enhanced readability |
Keypad | 2 operation keys |
Calibration | Manual calibration. MuniDock or Calicase allows automatic bump test and calibration |
Alarm | Wireless remote alarm notification, audible (95dB@30cm), vibration, visual (flashing bright red LEDs), and on-screen indication of alarm conditions Man Down Alarm with pre-alarm and real-time remote wireless notification |
Datalogging | 1000 Events (Software allows printing of Calibration Certificate) |
Charging and Communication | Charging with AC adapter or cable to PC |
PC comm for data download, monitor setup & firmware upgrades via cable, optional BLE (Bluetooth Low Energy), or MuniDock | |
Temperature | -4° to 122°F (-20°C to 50°C) |
Humidity | 0% to 95% relative humidity (non-condensing) |
IP Rating | IP-68 |
Safety Certifications | UL/cUL: Class I, Div 1, Group A, B, C, D |
T4, -20°C ≤ Tamb ≤ +50°C | |
EMC/RFI | |
EMC directive: 2004/108/EC | |
ATEX II 1G Ex da ia IIC T4 Ga | |
Warranty | 2-year including sensors |
3-years with NDIR-LEL/O2-LF/H2S/CO |