MIC300 Bromomethane CH3Br Gas Monitoring Equipments
●Fast and efficient gas detection function
① It can be used in 24 hours continuous online monitoring of single field gas concentration and the types for detection are more than 500 types.
●Diversified communication methods
① It is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission.
② Three-wire system 4 ~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output.
③ It is compatible with secondary instrument, data acquisition module, PLC, DCS system, and it is possible to drive the related equipment.
●Powerful and convenient humanized function
① Data recovery function; in case of mis-operation, it is possible
to select partial or full recovery.
② Multiple alarm modes, and multi-directional and threedimensional indication alarm states, includes: 2 sets of relay switch output, sound & light alarm (optional configuration).Alarm types include: concentration alarm, and failure alarm.
③ Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may becaused by human factors.
④ Zero-point automatic tracking; long-term use will not be affected by the zero drift.
⑤ Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements.
⑥ Broad operating temperatures: -40~+70℃, and temperature compensation is supported.
⑦ Intrinsically safe circuit design, explosion-proof, with Level II lightning protection, and anti-static capabilities. Meet the national standard, and it is resistant to the high-intensity pulse surge current. With the function of preventing the reverse connection. It is compliant with EMI, and EMC standards.
Fixed gas detector is mainly used in underground tunnels, sewage treatment plants, chemical plants, steel plants, coal mines, boiler rooms, oil pipelines, gas stations, indoor air quality testing, sterilization, frozen warehouses, underground corridors and other mixed gas scenarios.
Type | Fixed Gas Detector | ||||
Detection range | 0~ 10ppm 0~ 20ppm 0~50ppm 0~100ppm Other ranges can be customized | ||||
Resolution | 0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), Other ranges can be customized | ||||
Detection principle | Electrochemical, infrared, thermal conductivity, PID photoionization, and so on. Depending on the type of gas, range, field environment and user demand, Sensor can be customized | ||||
Sensor service life | Electrochemical principle: 2 ~ 3 years; Infrared principle: 5 ~ 10 years; Thermal conductivity: 5 years | ||||
Allowable error | ≤±3% F.S (other or higher precision levels can be customized) | ||||
Linearity | ≤±2% | Repeatability | ≤±2% | Uncertainty | ≤±2% |
Response time | T90≤30 seconds | Recovery time | ≤30 seconds | ||
Working environment | Temperature: -40 ℃ ~ + 70 ℃, humidity: ≤10 ~ 95% RH (regular) | ||||
Working voltage | 12 ~ 30VDC direct current the standard power supply for a single equipment is 24V, DC stabilized voltage switching power supply of 1A or greater than 1A | ||||
Power supply reference | 24V, 2.1A is possible to drive 40 units of toxic gas detector, or 15 units of flammable, infrared gas detector. | ||||
Working method | Fixed type installation, online detection, diffusion type measurement | ||||
Protection level | IP65 | ||||
Explosion-proof mark | ExdⅡCT6, certificate number: CNEx15.1283 | ||||
Exterior dimensions | 233×205×65mm (L×H×W) | ||||
Weight | 1.0 Kg | ||||
Standard accessories | Manual, qualification certificate, warranty card, outer packaging box |