Specifications
Brand Name :
Zetron
Model Number :
MS104K-L
Certification :
CE, ISO13485, ISO9001
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
1000 set/month
Delivery Time :
3-7 days
Packaging Details :
paper carton
Product Name :
Single Combustible Gas Detector Could Switch
Operating power supply :
DC3.7 V*2
Display :
LCD
Protection class :
IP68
Detection Range :
Depends on the site environment and user needs
Dimension :
Maximum size 167x64x62mm(LxWxH)
Weight :
Approx. 280g
Description

MS104K-L Single Gas Detector

OVERVIEW

All the cases require the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.

The main functions of MS104K-L portable gas detector are for The main functions of the MS104K-L portable gas detector are to quickly and accurately detect gas leaks or gas concentration exceeding the alarm limit. The main detection principles of gas detection are: electrochemical, infrared, catalytic combustion, thermal conductivity, PID photoionization, etc. The MS104K-L is widely used in firefighting, emergency rescue, confined space, petroleum, chemical industry, metallurgy, refining, gas, storage, medicine, environmental protection, air treatment and other occasions.

FEATURES

● Built-in pump suction measurement, can be switched to diffusion, diffusion + pump suction detection mode

● Pump clogging alarm

● LED lighting (optional)

● Unit free switching, unit optional: umol/mol, ppm, pphm, ppb, mg/m3, ug/m3, %Vol, %LEL

● 8-key operation, quick one-key calibration function

● Data storage, storage capacity of not less than 100,000 items

● Communication interface: TYPE-C, option: BluetoothFall alarm

● Data recovery function, part or all of the factory data recovery

● Maximum value, minimum value, weighted average value display

● Alarm mode setting Alarm mode: sound and light alarm, vibration alarm, voice alarm Alarm type: Concentration alarm, under pressure alarm, fault alarm, pump blockage alarm. Alarm mode: low alarm, high alarm, interval alarm, TWA/STEL alarm

● Misoperation recognition function, concentration calibration misoperation is automatically recognized and blocked

● Zero point auto-tracking, avoiding zero point drift.

● Multi-level calibration of target point

● Intrinsically safe circuit design, explosion-proof, shock-proof, anti-static, anti-radiation.

● Protection class IP68, rain and immersion, dustproof, anticorrosive

APPLICATION

It is widely used in areas where explosion-proof is required or toxic gas leaks, like underground channels or the mining industry, so as to protect the worker's life and avoid damage to the relevant equipment.

PARAMETER

Detection Factor Single gas (carbon monoxide CO, hydrogen sulfide H2S, oxygen O2, combustible gas Ex, carbon dioxide CO2, VOC, etc.), depending on the site environment and user requirements
Detection Range Depends on the site environment and user needs
Resolution 0.001ppm (0-10ppm high accuracy)/0.01ppm (0-10 ppm); 0.01ppm (0-100 ppm), 0.1ppm (0-1000 ppm), 1ppm (0-1000 ppm or more); 0.1%LEL;0.1%, 0.01%Vol
Detection Principle Electrochemical, catalytic combustion, infrared, thermal conductivity, semiconductor, PID photoionization, etc., depending on the range, site environment and user needs
Sensor life Electrochemical 2-3 years, catalytic combustion 2-3 years, infrared 5-10 years, thermal conduction 2-5 years, PID 2-3 years
Measuring method Built-in pump suction, can be switched to diffusion, diffusion + pump suction detection mode
Display LCD
Display content Real-time concentration, unit, gas name, alarm status, time, storage status, communication status, power, charging status, etc.
Detection accuracy Typical precision: ≤±3% FS (optional higher precision sensor) Uncertainty ≤±2%
Linearity ≤±3% Repeatability ≤±2%
Response time T90≤20 seconds Recovery time ≤30 seconds
Operating power supply DC3.7 V*2
Battery capacity 2500mAh rechargeable polymer battery, with over-charge, over-discharge, over-voltage, short-circuit, overheating protection function.
Environment Temperature: -20℃~+60℃, customizable -40℃~+70℃; Relative humidity: 10-95%RH
Communication Interface Standard Type-C (2 hours fully charged)
Data storage Standard capacity of not less than 100,000 items; support for local view, delete or data export, storage time interval arbitrary
settings
Interface language Chinese, English and other languages can be customized
Explosion-proof type Intrinsically safe ExiaⅡCT4Ga
Protection class IP68
Housing material High-strength corrosion-resistant fire-resistant polycarbonate and rubber protective cover, drop-proof wear-resistant anti-static,effective drop resistance ≥ 5 meters
Dimension Maximum size 167X64X62mm(L×W×H)
Weight Approx. 280g
Standard accessories Calibration cover, pump suction nozzle, manual, certificate of conformity, USB charger (including data cable), instrument
packaging color box
Optional accessories ① 0.2 meters swan neck sampling probe;
② activated carbon filter;
③ 0.4 meters stainless steel sampling handle (including 1 meter hose);
④ 0.9 meters retractable sampling handle (including 1 meter hose);
⑤ External Bluetooth printer.

Detected Gases Range Minimum Reading Detected Gases Range Minimum Reading
VOCs(VOC) 0-20ppm 0.01ppm Ethylene oxide (ETO) 0- 100%LEL 0. 1%LEL
VOCs(VOC) 0-200ppm 0. 1ppm Phosgene(COCL2) 0- 1ppm 0.001ppm
VOCs(VOC) 0-2000ppm 1ppm Phosgene(COCL2) 0- 10ppm 0.01ppm
VOCs(VOC) 0- 10000ppm 1ppm Silane(SiH4) 0- 1ppm 0.001ppm
Gas (EX) 0- 1000ppm 1ppm Silane(SiH4) 0-50ppm 0.01ppm
Gas (EX) 0- 100%LEL 0. 1%LEL Fluorine gas (F2) 0- 1ppm 0.001ppm
Gas (EX) 0- 100%VOL 0.01%VOL Fluorine gas (F2) 0- 10ppm 0.001ppm
Methane (CH4) 0- 100%LEL 0. 1%LEL Fluorine gas(F2) 0- 100ppm 0.01ppm
Methane (CH4) 0- 100%VOL 0.01%VOL Hydrogen Fluoride (HF) 0- 10ppm 0.01ppm
Oxygen (O2) 0-30%VOL 0.01%VOL Hydrogen Fluoride (HF) 0-50ppm 0.01ppm
Oxygen (O2) 0- 100%VOL 0.01%VOL Hydrogen Bromide(HBr) 0-50ppm 0.01ppm
Carbon Monoxide (CO) 0- 100ppm 0.01ppm Ethylborane(B2H6) 0- 10ppm 0.001ppm
Carbon Monoxide (CO) 0- 1000ppm 0. 1ppm Arsine(AsH3) 0- 1ppm 0.001ppm
Carbon Monoxide (CO) 0-2000ppm 1ppm Arsine(AsH3) 0- 10ppm 0.001ppm
Carbon Monoxide (CO) 0-5000ppm 1ppm Germanium(GeH4) 0- 1ppm 0.001ppm
Carbon Monoxide (CO) 0- 10000ppm 1ppm Germanium(GeH4) 0- 10ppm 0.001ppm
Carbon dioxide (CO2) 0-5000ppm 1ppm Germanium(GeH4) 0-50ppm 0.01ppm
Carbon dioxide (CO2) 0-50000ppm 1ppm Hydrazine, hydrazine hydrazide (N2H4) 0- 1ppm 0.001ppm
Carbon dioxide (CO2) 0-5%VOL 0.01%VOL Hydrazine, hydrazine hydrazide (N2H4) 0-300ppm 0. 1ppm
Carbon dioxide (CO2) 0-20%VOL 0.01%VOL Tetrahydrothiophene (THT) 0-50mg/m3 0.01 mg/m3
Carbon dioxide (CO2) 0- 100%VOL 0.01%VOL Bromine (Br2) 0- 10ppm 0.01ppm
Formaldehyde (CH2O) 0- 10ppm 0.01ppm Bromine gas (Br2) 0-50ppm 0.01ppm
Formaldehyde (CH2O) 0-50ppm 0.01ppm Sulfur dioxide (SO2) 0-20ppm 0.01ppm
Formaldehyde (CH2O) 0- 100ppm 0.01ppm Sulfur dioxide (SO2) 0- 100ppm 0.01ppm
Formaldehyde (CH2O) 0- 1000ppm 1ppm Sulfur Dioxide(SO2) 0- 1000ppm 0. 1ppm
Ozone (O3) 0- 1ppm 0.001ppm Sulfur dioxide (SO2) 0-5000ppm 1ppm
Ozone (O3) 0- 10ppm 0.01ppm Nitric oxide (NO) 0-20ppm 0.01ppm
Ozone (O3) 0- 100ppm 0.01ppm Nitric Oxide (NO) 0- 100ppm 0.01ppm
Ozone (O3) 0-2000ppm 1ppm Nitric Oxide (NO) 0- 1000ppm 0. 1ppm
Hydrogen Sulfide (H2S) 0- 10ppm 0.01ppm Nitric Oxide (NO) 0-5000ppm 1ppm
Hydrogen sulfide (H2S) 0- 100ppm 0.01ppm Nitrogen Dioxide (NO2) 0-20ppm 0.01ppm
Hydrogen sulfide (H2S) 0-500ppm 0. 1ppm Nitrogen dioxide 0- 100ppm 0.01ppm
Hydrogen sulfide (H2S) 0-2000ppm 1ppm Nitrogen dioxide 0- 1000ppm 0. 1ppm
Hydrogen Cyanide(HCN) 0- 100ppm 0.01ppm Nitrogen Dioxide (NO2) 0-2000ppm 1ppm
Hydrogen Chloride(HCL) 0-20ppm 0.01ppm Nitrogen Oxides (NOX) 0- 100ppm 0.01ppm
Hydrogen chloride (HCL) 0-200ppm 0. 1ppm Nitrogen Oxides (NOX) 0-500ppm 0. 1ppm
Phosphine (PH3) 0-5 ppm 0.001ppm Nitrogen oxides (NOX) 0-2000ppm 1ppm
Phosphine (PH3) 0-20 ppm 0.01ppm Chlorine (CL2) 0-20ppm 0.01ppm
Phosphine(PH3) 0-2000 ppm 1ppm Chlorine (CL2) 0-200ppm 0. 1ppm
Chlorine dioxide (CLO2) 0- 1ppm 0.001ppm Ammonia (NH3) 0- 10ppm 0.01ppm
Chlorine dioxide (CLO2) 0- 10ppm 0.01ppm Ammonia (NH3) 0- 100ppm 0.01ppm
Chlorine dioxide (CLO2) 0- 100ppm 0.01ppm Ammonia(NH3) 0- 1000ppm 0. 1ppm
Ethylene oxide (ETO) 0- 100ppm 0.01ppm Ammonia gas (NH3) 0-5000ppm 1ppm
Ethylene oxide (ETO) 0- 1000ppm 0. 1ppm Ammonia(NH3) 0- 100%LEL 0. 1%LEL

LED Lighting Single Gas Monitor Zetron MS104K-L Between Diffusion And Pumped Type

LED Lighting Single Gas Monitor Zetron MS104K-L Between Diffusion And Pumped Type

Send your message to this supplier
Send Now

LED Lighting Single Gas Monitor Zetron MS104K-L Between Diffusion And Pumped Type

Ask Latest Price
Watch Video
Brand Name :
Zetron
Model Number :
MS104K-L
Certification :
CE, ISO13485, ISO9001
Place of Origin :
China
MOQ :
1
Payment Terms :
T/T, Western Union, MoneyGram
Contact Supplier
video
LED Lighting Single Gas Monitor Zetron MS104K-L Between Diffusion And Pumped Type
LED Lighting Single Gas Monitor Zetron MS104K-L Between Diffusion And Pumped Type
LED Lighting Single Gas Monitor Zetron MS104K-L Between Diffusion And Pumped Type

Beijing Zetron Technology Co., Ltd

Verified Supplier
4 Years
beijing, beijing
Since 2001
Business Type :
Distributor/Wholesaler, Agent, Seller
Total Annual :
10000000-15000000
Employee Number :
50~80
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement