MIC200 Fixed Online Gas Detector
MIC100 Series require no hot work permit and the PID sensor is accessible and changeable in a matter of seconds.
Strong, durable, and explosion-proof shell and fluorocarbon surface treatment processes are suitable for use at a variety of hazardous places and corrosive environments.
=
Gas | Nitric Oxide | Sensor | Electrochemical |
Range | 0-500,1000,2000ppm Can be customized | Resolution | 0.1 ppm; Can be customized |
Smapling Method | diffusion/pump | Control Method | Controller/Infrared remote control |
Working Temp | -20 ℃ ~ + 70 ℃;(Standard Values) -40 ℃ ~ + 80 ℃;(Limit Value) | Humidity | 10 ~ 95% RH |
Voltage | ≤2.5 W(DC24V) | Power | 12~30VDC |
Protection level | IP65 | Explosion-proof | Exd Ⅱ CT6 |
Alarm | Audible;Light(option) | Display | LCD/without LCD Display |
Cable | PVVP3 * 1.0mm 2 | Transmission Distance | ≤1000m |
Installation | Wall-mounted;Ceiling-mounted;Vertical pipe-mounted; Horizontal pipe-mounted | ||
Size(mm) | 180*140*92 | Weight(Kg) | 1.6 |
Kit | Manual, qualification certificate, warranty card, outer packaging box |
All the cases which requires the fixed installation, and online detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.