UV-2300C Ozone Concentration Analyzer
Ozone concentration detector equipment every 1 hour automatic zero point blowing once to ensure the stability of the zero point, to prevent the zero point drift affect the accuracy of the detection concentration, the gas flow, pressure, and flow rate remains unchanged during the calibration zero, to prevent the impact of airflow on the calibration zero, to ensure that the equipment can operate continuously 24 hours a day.
This ozone concentration analyzer is mainly used for ozone concentration measurement in the ozone generator pipeline, and can continuously detect the ozone concentration in the ozone generator outlet pipeline online. It is mainly used for the continuous detection of ozone gas in various industrial environments, and can also be used to detect ozone gas in operating pipelines, vessels, and other settings. Widely used in pharmaceutical, chemical, municipal, sewage treatment, and other industries, the ozone generator outlet concentration, and ozone generator output measurement.
The ozone concentration detector calculates the current ozone concentration value by measuring the change in light signal intensity before and after the absorption of ultraviolet light by ozone. Equipment using an advanced dual-optical UV light source system, equipped with a lamp intelligent management system, after power on the UV lamp can quickly reach the measurement state, using the German separation of light cell technology, the equipment has no leakage, high-pressure resistance, resistance to the impact of large flow sampling gas, easy to clean, easy maintenance, simple operation, low cost of use and other characteristics.
Measuring range | 0-300g/Nm3, 0-200g/Nm3, 0-100g/Nm3, 0-14%WT, 0-1000ppm |
Display resolution | 0.01 g/m3, 0.01ppm Note: 1mg/L=1g/m3=467ppm |
Display unit | g/Nm3 , mg/NL, %WT , ppm , mg/Nm3 |
Sampling method | Positive pressure sampling , Negative pressure sampling |
Content interface | Ozone concentration , Temperature compensation, Pressure compensation, Mass flow and production display |
Light source life | About 30000-50000 hours |
Display interface | 4.3 inch touch screen operation interface |
Auxiliary functions | Temperature compensation, pressure compensation |
Sampling flow rate | 0.5L±0.2L/min |
Input pressure | <0.1MPa |
Concentration error | < 0.3%FS |
Linearity error | < 0.2%FS |