Portable UV Flue Gas Analyzer
It is new portable type that adopts the UV DOAS, NDIR, and electrochemical technology to measure the concentration of SO2, NO, CO, CO2, HC, and O2 from stack or boiler emission gases, with optional gas temperature, velocity, combustion efficiency, air coefficient, etc.
Gas conditioning device features
General Parameter | |
Measurement | SO2, NO, CO, CO2, O2 |
Technology | SO2, NO, CO: Dual-beam micro-flow NDIRtechnology |
CO2: NDIR technology | |
O2: long lifetime ECD technology | |
Range | S02, NO: (0-500-2000)mg/m |
CO (0-5000)mg/m | |
CO2,O2: (0-25) % | |
(Note: Measurement range can be customized) | |
Resolution | SO2, NO, CO: 1mg/m3 |
CO2,O2 : 0. 01% | |
Precision | SO2, NO, CO: 1mg/m3 |
Repeatability | < 2% |
Stability | <2%S/24h |
Response time (T90) | 30s |
Warm up time | 5min |
Communication interface | USB, or Dot matrix printer |
Power supply | AC 220 v + 10%, 50 Hz |
Inlet gas flow | (0.7-1.2)L/min |
Display | LCD display |
Working Environment | |
Work temperature | 0-50 ℃ |
Relative humidit | 5-85% |
Ambient pressure | 86-108kPa |
Dimensions | |
Size | 275mm*470mm*175mm |
Weight | 7.2 kg |
Boiler, furnace exhaust emission gas and combustion efficiency monitoring, cement production line process and security monitoring, CEMS integration.