Ms400-CH4 Portable Gas Detector for Methane Monitoring and Carbon Emission Analysis
1. Specially Designed for Use With Its Internal Pump, Optimized for Your Requirements
The MS400 is equipped with a very powerful internal pump.
It can be connected with hoses of up to 45 meters in length.
This means the pump is only operated when you actually need it. That saves energy, reduces wear and tear, and thereby extends the lifespan of the pump.
2. Compact Design, Easy to Use
Handy and durable, the MS400 is intuitive to operate single-handedly using three function keys. The easy-to-read color display clearly lays out all the information for you. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.
3. Large Data Storage Management, Release, and Documentation In No Time
Standard configuration is the data storage capacity for 100, 000 entries.
Real-time storage and fixed time storage are supported, or only the data of the alarm concentration will be stored.
It is supported to use the localhost to view, delete data, and upload the data via USB interface to the computer for data analysis or printing.RS485 communication is an optional configuration.
Gases to be detected | Arbitrary combination of 1 ~ 4 types of gases such as toxic gases, oxygen gas, carbon dioxide, inflammable and explosive gases, TVOC, and so on. Optional configuration: temperature and humidity measurements. |
Application scenarios | All the cases which requires the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on. |
Detection range | 0 ~ 1, 10, 100, 1000, 5000, 50000, 100000ppm, 200 mg/L, 100%LEL, 20%, 50%, 100%Vol, can be selected; and other ranges can be customized. |
Resolution | 0.01ppm or 0.001ppm (0 ~ 10 ppm); 0.01ppm (0 ~ 100 ppm), 0.1ppm (0 ~ 1000 ppm), 1ppm (0 ~ 10000 ppm or more), 0.01 mg/l (0 ~ 200 mg/l), 0.1% LEL, 0.01%LEL 0.001% Vol |
Detection principle | Electrochemical, catalytic combustion, infrared, thermal conductivity,PID photoionization, and so on. Depending on the type of gas, range, field environment and user demand. |
Sensor service life | Electrochemical principle: 2 ~ 3 years; Oxygen gas: 2 years or 6 years can be selected; Infrared principle: 5 ~ 10 years; Catalytic combustion: 3 years; Thermal conductivity: 5 years; PID photoionization: 2 ~ 3 years. |
Allowable error | ≤±3% F.S (other precision levels can be customized) |
Working environment | Temperature: -40 ºC ~ + 70 ºC, humidity: ≤10 ~ 95% RH, and built-in filters can be used in high humidity or high dust environment. |
All the cases require the portable rapid detection of gas concentrations such as petroleum, chemical, pharmaceutical, environmental protection, combustion gas distribution, warehousing, smoke gas analysis, air governance, and so on.