Double Suction Split Case Fire Fighting Water Pump COS-F125-290 (1250-1500gpm 80-120m)
Description
A fire fighting water pump is a centrifugal pump which is used for pumping fire-fighting water. Fire-fighting pumps can be designed for transportable use (e. g. on fire-fighting vehicles or as portable fire pumps) or for stationary use (e. g. hydrants, sprinkler systems).
The XSF series Horizontal Split Case Fire Fighting Water Pumps are engineered for reliable operation upon stationary use. All fabricated parts are standardized and accurately machined for true alignment, increasing overall durability. Precision balancing of all rotating components provides mechanical dependability, reliable operation and minimal maintenance. Impellers are constructed with double inlets that practically eliminated end thrust while boosting operating efficiency.
Stationary fire-fighting pump
The most important and most common fire-fighting systems are sprinkler systems. Sprinkler systems consist of several sprinkler heads which are connected via a piping system. Large heat automatically triggers the sprinkler heads in defined intervals to protect the rooms they are installed in. Sprinkler systems are automatic fire-fighting systems.
Fire hydrants are another type of fire-fighting system. Hydrants are activated manually. Depending on their type they are either designed for general use or for activation by fire-fighters only.
Wet-pipe sprinkler systems are the most common type of sprinkler system. In this system, the pipelines are permanently under pressure and filled with water. The fire-fighting water will be discharged immediately as soon as one or several sprinklers have been activated. In dry-pipe sprinkler systems pipelines laid in areas which are likely to be effected by frost/freezing are filled with air.
Depending on the hazard class, sprinkler systems may be required to be supplied with water from two independent sources, using either one or two fire-fighting pumps. If two pumps are used, two independent energy sources may have to be provided, depending on the applicable regulations.
Features
* Exceptional hydraulic efficiencies
* Double entry reduce end thrust force, increase efficiency and bearing life
* Stainless steel impellers and shaft as standard
* Reduced efficiency degradation
* Comply to FM and/or UL standards (NFPA 20, UL448 and FM1311)
Parameters of COS-F series Split Case Fire Fighting Water Pump
Flow Capacity | 1250-1500 gpm | Delivery Head | 80-120 m |
Inlet/Outlet Dia. | DN200/DN125 mm | Working Pressure | ≤ 1.8 MPa |
Liquid Temperature | 0 - 80 ℃ | Driven By | Electric Motor / Diesel Engine |
Seal Type | Mechanical seal / Gland packing | Liquid | Clean water or similar |
Material of Construction | Cast Iron / Cast Steel / S.S304 / S.S316 / Duplex S.S2205 |
Main Parts Configuration
To meet the NFPA20 standards, the pump was constructed with the following materials:
Parts Name | Material of Construction (Comply with NFPA20) |
Pump Case | Ductile Iron |
Shaft | 40Cr / 35CrMo / 42CrMo/S.S420 |
Shaft Sleeve | S.S304 |
Impeller | S.S304/Bronze |
Wearing Ring | S.S304/Bronze |
Bearing | China Make/NSK/SKF |
Seals | PTFE Packing Seals/Mechanical Seals |