Parameters | Min | Typical | Max | Unit | |
Operation Wavelength | DWDM channels | | |||
Insertion Loss – passband * | Gaussian | | ≤ 4.0 | | dB |
Flat top | | ≤ 5.0 | | ||
Channel Bandwidth | | ± 0.11 | | nm | |
Uniformity | | ≤ 1.0 | | dB | |
Isolation @Add/Drop Channel Durability | Adjacent | | ≥ 30 | | dB |
Non-adjacent | | ≥ 40 | | ||
PDL | | ≤ 0.5 | | dB | |
PMD | | ≤ 0.5 | | ps | |
Directivity | | ≥ 50 | | dB | |
Return Loss | | ≥ 45 | | dB | |
Power Handling | | 300 | | mW | |
Operating Temperature | 0 | | +70 | °C | |
Storage Temperature | -40 | | +85 | °C |
Operating Wavelength | 1525nm-1570nm (C-band) | Number of Channels | 40 Channels |
Channel Spacing | 100GHz(0.8nm) | Channel Wavelength | C21 – C60 or Specify |
Center Wavelength Bandwidth | ±12.5GHz | Center Wavelength Accuracy | ±0.05nm |
-1dB Bandwidth | Guassian: ≥0.22dB, Flat-top: ≥0.4dB | -3dB Bandwidth | Guassian: ≥0.42dB, Flat-top: ≥0.55dB |
-20dB Bandwidth | Guassian: ≤1.2dB, Flat-top: ≤1.2dB | Pass band Insertion Loss | Guassian: ≤4.0dB, Flat-top: ≤5.0dB |
Total Cross Talk | ≥22dB | Insertion Loss Uniformity | ≤1.5dB |
Adjacent Isolation | ≥25dB | Non-Adjacent Isolation | ≥30dB |
Passband Ripple | ≤0.7dB | 1310nm Port Pass Band Width | 1260nm~1360nm |
Insertion Loss @ 1% Mon | ≤26dB | Insertion Loss @1310 port | ≤1.5dB |
Polarization Dependent Loss | ≤0.5dB | Polarization Mode Dispersion | ≤0.1ps |
Return Loss | ≥45dB | Directivity | ≥50dB |
Chromatic Dispersion(ps/nm) | -20 – +20 | Max Optical Power | 300mW |
Operating Temperature(℃) | -5 to 65°C | Storage Temperature(℃) | -40 to 85°C |
Prefi | Ch. Spacin | Number of Channel | Type | 1st ITU Channel Number * (for example) | Configuration | Monitor | Connector |
AAWG- | 100G = 1 | 40 Channel = 40 | Flat top = 1 Gaussian = 2 | 1560.61nm = 21 1588.98nm = 23 | MUX or DEMUX=1 MUX+DEMUX=2 | NO monitor port = 1 With monitor port = 2 Special = 0 | LC/UPC = 8 Special = 0 |