Specifications
Brand Name :
KNKONG
Model Number :
VS1-12
Certification :
CB,ISO,IEC
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
1000 Unit per month
Delivery Time :
15 working days
Packaging Details :
Standard export packaging
Voltage :
12KV
Current :
630-2000A
Breaking current :
20-25KA
Type :
Fixed
Phase spacing :
205-310
Brand :
KNKONG
Description

205 Phase Spacing 25KA breaking Fixed Circuit Breaker

Voltage: 12KV

Current: 630-2000A

Breaking current: 20KA

Type: Fixed

Phase spacing: 205-310

Product overview

VS1-Series circuit breaker is independently developed by Knkong based on the advanced design concept; it adopts a modularized mechanism, which is easy for installation, maintenance, testing, and operation. As compared with conventional VS1 circuit breaker. it features higher operation stability, higher safety, and extended service life. The product can satisfy customer's demand for application in 12kv and 24kV power transmission and distribution systems, which is extensively applied in such industries as power, energy, petrochemical engineering, metallurgy, manufacture, traffic, building, and environmental protection as well as large-scale enterprises and national key projects.

VS1-Series circuit breaker features high stability and high reliability

In terms of mechanisms, VS1-Series vacuum circuit breakers are given special optimization to transmission parts. Modular spring mechanisms have such advantages as convenient maintenance, short power-off maintenance, high versatility of parts, and boast better compatibility with vacuum interrupters which greatly improves the technical parameters and delivers more excellent performance.

Normal service condition

Altitude ≤1000m
Ambient temperature Max +40℃
Min -15℃

Ambient humidity:

Maximum average humidity

24 hours ≤95%
1 month ≤90%
Maximum water vapor pressure 24 hours ≤2.2kpa
1 month ≤1.8kpa

Solar radiation is negligible. Vibration from the outside of switchgear and control gears is negligible. The ambient air has no obvious pollution of dust smoke, corrosive or combustible gases, steams or smog

Special service condition

Special operating conditions are to be agreed on by the manufacturer and user the manufacturer must be consulted in advance about each special operating condition:

Site altitude over 1000m

- Allow for the reduction in the dielectric strength of the air

- Or plateau type circuit breaker should be ordered, which shall meet

corresponding insulation requirements.

Increased ambient temperature

- Current carrying capacity is reduced

- Provide additional ventilation for heat dissipation

Other considerations should be consulted with the manufacturer according to Section 2.2 in IEC 62271-1

VS1-Series circuit breaker features high stability and high reliability

In terms of mechanisms, VS1-Series vacuum circuit breakers are given special optimization to transmission parts. Modular spring mechanisms have such advantages as convenient maintenance, short power-off maintenance, high versatility of parts, and boast better compatibility with vacuum interrupters which greatly improves the technical parameters and delivers more excellent performance.

Technical Parameters

No. Item Unit Parameter
1 Rated voltage KV 12
2 Rated frequency Hz 50/60
3

Rated insulation level

1min power frequency withstand voltage(r. m. s)

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

4

Rated current

A

630 630 1250 1600
1250 1250 1600 2000
2000 2500
2500 3150
4000
5 Rated short-circuit breaking current

KA

20 25 31.5 40
6 Rated short-time withstand current 20 25 31.5 40
7 Rated short-circuit marking current 50 63 80 100
8 Rated peak withstand current 50 63 80 100
9 Rated duration of short-circuit s 4
10 Rated operating sequence O-0.3s-O/C-180s-O/C
11 Breaking times of rated short-circuit current Times 30/20 times(40KA)
12 Mechanical endurance Ops 20000
13 Rated single capacitor bank breaking current

A

630
14 Rated back-to-back capacitor bank breaking current 400
15 Double-earth fault breaking current 27.4
16 Allowable maximum contact erosion

mm

3
17 Clearance between open contacts 10±1
18 Over stroke 3.5±0.5
19 Non-simultaneity of 3-phase opening and closing

ms

≤2
20 Bounce duration of contact closing ≤2
21 Average breaking speed (instant breaking 6mm)

m/s

1.1±0.2
22 Average making speed 0.8±0.2
23 Making time

ms

≤100
24 Breaking time ≤50

25

Resistance of each phase main circuit

μ Ω

630A ≤50
1250A ≤45
1600A~2000A ≤35
≥2500A ≤25
26 Contact breaking bounce amplitude mm ≤2

27

Rated operating voltage Rated operating voltage(V)AC/DC

V

24* 110 220
Scope of normal operation voltage Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28 Rated voltage of energy storage motor V AC110/220, DC110/220
29 Energy storage time S ≤15

Send your message to this supplier
Send Now

205 Phase Spacing 25KA Breaking Fixed Circuit Breaker

Ask Latest Price
Brand Name :
KNKONG
Model Number :
VS1-12
Certification :
CB,ISO,IEC
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, T/T, Western Union
Contact Supplier
205 Phase Spacing 25KA Breaking Fixed Circuit Breaker

Knkong Electric Co.,Ltd

Active Member
5 Years
henan, zhengzhou
Since 2012
Business Type :
Manufacturer
Total Annual :
1000000-9000000
Employee Number :
50~100
Certification Level :
Active Member
Contact Supplier
Submit Requirement