Specifications
Brand Name :
KNKONG
Model Number :
VS1-12
Certification :
CB,ISO,IEC
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
1000 Unit per month
Delivery Time :
15 working days
Packaging Details :
Standard export packaging
Voltage :
12KV
Current :
630-2000A
Breaking current :
20-25KA
Type :
withdrawable
Original :
China
Manufactory :
KNKONG
Description

VS1-12 withdrawable Vacuum Circuit Breaker 12KV 630-2000A

Voltage: 12KV

Current: 2000A

Breaking current: 20KA

Type: withdrawable

Product overview

VS1-Series circuit breakers are complete independently developed by Knkong based on the advanced design concept; it adopts a modularized mechanism, which is easy for installation, maintenance, testing, and operation. As compared with conventional VS1 circuit breaker. it features higher operation stability, higher safety, and extended service life. The product can satisfy customers demand application in 12kv and 24kV power transmission and distribution systems, which is extensively applied in such industries as power, energy, petrochemical engineering, metallurgy, manufacture, traffic, building, and environmental protection as well as large-scale enterprises and national key projects

Normal service condition

Altitude ≤1000m
Ambient temperature Max +40℃
Min -15℃

Ambient humidity:

Maximum average humidity

24 hours ≤95%
1 month ≤90%
Maximum water vapor pressure 24 hours ≤2.2kpa
1 month ≤1.8kpa

Special service condition

For special operating conditions, please consult the manufacturer:
The site altitude exceeds 1000m
-Allows to reduce the dielectric strength of air
-Or order a high prototype circuit breaker, which should meet
Corresponding insulation requirements.
Ambient temperature rise
-Reduced current carrying capacity
-Provide additional ventilation for heat dissipation
Other precautions should be negotiated with the manufacturer according to section 2.2 of IEC 62271-1

Technical Parameters

No. Item Unit Parameter
1 Rated voltage KV 12
2 Rated frequency Hz 50/60
3

Rated insulation level

1min power frequency withstand voltage(r. m. s)

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

4

Rated current

A

630 630 1250 1600
1250 1250 1600 2000
2000 2500
2500 3150
4000
5 Rated short-circuit breaking current

KA

20 25 31.5 40
6 Rated short-time withstand current 20 25 31.5 40
7 Rated short-circuit marking current 50 63 80 100
8 Rated peak withstand current 50 63 80 100
9 Rated duration of short-circuit s 4
10 Rated operating sequence O-0.3s-O/C-180s-O/C
11 Breaking times of rated short-circuit current Times 30/20 times(40KA)
12 Mechanical endurance Ops 20000
13 Rated single capacitor bank breaking current

A

630
14 Rated back-to-back capacitor bank breaking current 400
15 Double-earth fault breaking current 27.4
16 Allowable maximum contact erosion

mm

3
17 Clearance between open contacts 10±1
18 Over stroke 3.5±0.5
19 Non-simultaneity of 3-phase opening and closing

ms

≤2
20 Bounce duration of contact closing ≤2
21 Average breaking speed (instant breaking 6mm)

m/s

1.1±0.2
22 Average making speed 0.8±0.2
23 Making time

ms

≤100
24 Breaking time ≤50

25

Resistance of each phase main circuit

μ Ω

630A ≤50
1250A ≤45
1600A~2000A ≤35
≥2500A ≤25
26 Contact breaking bounce amplitude mm ≤2

27

Rated operating voltage Rated operating voltage(V)AC/DC

V

24* 110 220
Scope of normal operation voltage Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28 Rated voltage of energy storage motor V AC110/220,DC110/220
29 Energy storage time S ≤15

Operation safety

With anti-maloperation locking protection these circuit breakers, working in switchgear cabinets, can realize "five-protection" interlocking functions, avoiding malapert and maximizing the protection of an operator's personal safety.

Only when the circuit breaker and earthing switch are in the disconnected position can the truck of circuit breaker be racked to the service position from the test position

The circuit breaker can be closed only when in the service/test position.

With the circuit breaker closed its truck cannot be racked in or racked out which can be realized only when the circuit breaker is in the disconnected position.

The circuit breaker in a closed position cannot be racked out from the service position to the test position.

The circuit breaker cannot be closed while it is being racked in.

When the circuit breaker is closed, if the closing signal fails to be removed timely, the internal anti-trip control circuit will cut off the closing circuit to prevent multiple reclosing (optional).

If the electric closing lockout is selected, the circuit breaker will be unable to be closed when the secondary circuit fails to provide power or the power provided fails to meet the normal operation of the locking electromagnet(optional).

Send your message to this supplier
Send Now

2000A 12KV Withdrawable Circuit Breaker Modularized Mechanism

Ask Latest Price
Brand Name :
KNKONG
Model Number :
VS1-12
Certification :
CB,ISO,IEC
Place of Origin :
China
MOQ :
1
Payment Terms :
L/C, T/T, Western Union
Contact Supplier
2000A 12KV Withdrawable Circuit Breaker Modularized Mechanism

Knkong Electric Co.,Ltd

Active Member
5 Years
henan, zhengzhou
Since 2012
Business Type :
Manufacturer
Total Annual :
1000000-9000000
Employee Number :
50~100
Certification Level :
Active Member
Contact Supplier
Submit Requirement