Specifications
Brand Name :
SUMAIRUI GAS
Model Number :
OSM
Certification :
ISO9001, CE, BV, SGS, TUV, ASME, GOST,NB,NR ETC
Place of Origin :
SUZHOU, CHINA
MOQ :
1 set
Price :
Negotiable
Payment Terms :
L/C, T/T, Western Union, MoneyGram
Supply Ability :
100 sets/months
Delivery Time :
30-45 days
Packaging Details :
Exporting wooden case /Film packing
Material :
Mild steel/Stainless steel
Certificates :
CE, ISO, ASME, GOST, KGS, NB etc
Capacity :
1000 CFM
Purity :
95%-99.9%
Pressure :
500 PSI
Container :
Yes
Movable :
Yes
Application :
Purging
Condition :
New
Warranty :
1 Year
Voltage :
220v/380v/50-60hz
Weight :
Actual Weight)
Dimension(l*w*h) :
Actual Size
Power(w) :
0.5KW
Color :
White/customized
Technology :
Membrane
Name :
nitrogen generator
Description

Membrane modular N2 generator for the Bacteria Elimination with capacity 500 scfm purity 95% 500 psi by CE certificates

How does membrane technology work?

Membrane nitrogen generators are based on a simple working principle. The main part of a membrane generator is the membrane module (+- 10cm in diameter), filled with small, hollow polymer fibers. First, dry, clean compressed air enters and due to the structure of these fibers parts of the air will flow to the outside of the fiber. This process is called permeation. During this process, water, oxygen and some of the argon exit through the membrane sides of the fibers. In the end, only nitrogen will remain. This is possible since different molecules permeate at different speeds. H2O will permeate very quickly, oxygen takes a little longer. Argon and Nitrogen permeate rather slowly, meaning that they will remain in the fibers long after the H2O and oxygen are gone (some of the Argon will permeate as well, but it would be inefficient to completely remove it from the air stream). Learn more about Nitrogen purity here. Because of the permeation through the fiber wall, an overpressure would occur inside the membrane housing. The fibers would clog and the permeation efficiency would be significantly lowered. To prevent that from happening there is an opening in the housing, the permeate vent, where these 'exhaust' gases (including H2O, oxygen and Argon) can escape.

Modular Membrane Nitrogen Generator Capacity 500psi Bacteria Elimination 500 Scfm

Nitrogen purity and requirements for the intake air

It is very important for the intake air to be clean and dry before it enters the membrane. If this is not the case, the shallow fibers will quickly clog. In order to prevent this from happening, correct air treatment of the feed air has to be installed. In some cases the needed filters and dryers will already be built into the generator itself. This would mean that, in some cases, no additional filters should be installed between the compressor and generator. The fibers of the membrane can handle water vapor without much problems. It is however very important that the air doesn't contain liquid water, since this will have a detrimental impact on the membrane. Therefore, it is required for a good water separation solution to be in place upstream the generator, a refrigerant dryer for example. Taking care of the intake air of the generator will protect the membrane and ensure a long lifetime. Take a look at a typical installation below.

Choosing between a Membrane and PSA generator

Since the air factor is generally lower in PSA generators, which results in lower operating costs, you might think that choosing between the two is an easy choice. However, there are some notable advantages to using a membrane generator. The first one being the simpler working principle of membrane generators, this affects maintenance costs and results in a smaller footprint of the installation. They also start up faster and are a lot quieter than PSA generators, who typically have to cope with their blow-off noises at the end of each cycle. This last advantage makes a membrane nitrogen generator more suitable for places in which there are a lot of people working. When selecting the right type of generator, it's wise to look at the application it will be used for and then, considering the total package of (dis)advantages, make a choice.

Modular Membrane Nitrogen Generator Capacity 500psi Bacteria Elimination 500 Scfm

Item Nitrogen purity (Nm3/hr) Dimensions

Weight

90% 95% 99% 99.5% 99.9% (L*W*H) mm KG
OSM15 135 61 23 15 6.5 450*300*1300 100
OSM30 270 122 46 30 13 550*500*1300 140
OSM60 540 244 92 60 26 900*850*1300 200
OSM120 1080 488 184 120 52 1200*1000*1500 280
OSM180 1620 732 276 180 78 1500*1200*1500 400
OSM240 1890 854 322 240 104 1800*1200*1600 520
OSM300 2700 1220 460 300 130 2300*1350*1800 600
OSM450 4050 1830 690 450 195 3850*1500*2000 800
OSM525 4725 2135 805 525 227.5 4200*1550*2100 950
OSM600 5400 2440 920 600 260 5000*1800*2250 1050
OSM675 6075 2745 1035 675 292.5 5500*1800*2350 1250
OSM750 6750 3050 1150 750 325 5850*1850*2400 1500
OSM900 8100 3660 1380 900 390 6500*1950*2400 1700
OSM1050 9450 4270 1610 1050 455 7800*2100*2450 1950
OSM1500 13500 6100 2300 1500 650 10500*2300*2600 2100
OSM1800 16200 7320 2760 1800 780 13000*2350*2600 2600

Modular Membrane Nitrogen Generator Capacity 500psi Bacteria Elimination 500 Scfm

Send your message to this supplier
Send Now

Modular Membrane Nitrogen Generator Capacity 500psi Bacteria Elimination 500 Scfm

Ask Latest Price
Brand Name :
SUMAIRUI GAS
Model Number :
OSM
Certification :
ISO9001, CE, BV, SGS, TUV, ASME, GOST,NB,NR ETC
Place of Origin :
SUZHOU, CHINA
MOQ :
1 set
Price :
Negotiable
Contact Supplier
Modular Membrane Nitrogen Generator Capacity 500psi Bacteria Elimination 500 Scfm

Suzhou Sumairui Gas System Co.,Ltd.

Verified Supplier
3 Years
suzhou
Since 2014
Business Type :
Manufacturer
Total Annual :
15000000-20000000
Employee Number :
85~100
Certification Level :
Verified Supplier
Contact Supplier