Compact configuration. Robust capacity. nitrogen membrane plants are a powerhouse unit capable of producing nitrogen up to 70,000 scfh with a range of purities up to 99.5% and are suitable for applications across a wide range of nitrogen needs from inerting warehouses to beverage dispensing and tire filling applications.
Our advanced selective permeating technology housed in a fully skidded unit is engineered for fast installation, low maintenance and simple operation.
In a membrane system, a compressed air stream flows through multiple membrane modules that contain thousands of hollow membrane fibers that each removes oxygen, water, and carbon dioxide, allowing nitrogen to pass through. Membrane systems typically produce 95-99.5% nitrogen purity.
Item | Nitrogen purity (Nm3/hr) | Dimensions | Weight | ||||
90% | 95% | 99% | 99.5% | 99.9% | (L*W*H) mm | KG | |
OSM15 | 135 | 61 | 23 | 15 | 6.5 | 450*300*1300 | 100 |
OSM30 | 270 | 122 | 46 | 30 | 13 | 550*500*1300 | 140 |
OSM60 | 540 | 244 | 92 | 60 | 26 | 900*850*1300 | 200 |
OSM120 | 1080 | 488 | 184 | 120 | 52 | 1200*1000*1500 | 280 |
OSM180 | 1620 | 732 | 276 | 180 | 78 | 1500*1200*1500 | 400 |
OSM240 | 1890 | 854 | 322 | 240 | 104 | 1800*1200*1600 | 520 |
OSM300 | 2700 | 1220 | 460 | 300 | 130 | 2300*1350*1800 | 600 |
OSM450 | 4050 | 1830 | 690 | 450 | 195 | 3850*1500*2000 | 800 |
OSM525 | 4725 | 2135 | 805 | 525 | 227.5 | 4200*1550*2100 | 950 |
OSM600 | 5400 | 2440 | 920 | 600 | 260 | 5000*1800*2250 | 1050 |
OSM675 | 6075 | 2745 | 1035 | 675 | 292.5 | 5500*1800*2350 | 1250 |
OSM750 | 6750 | 3050 | 1150 | 750 | 325 | 5850*1850*2400 | 1500 |
OSM900 | 8100 | 3660 | 1380 | 900 | 390 | 6500*1950*2400 | 1700 |
OSM1050 | 9450 | 4270 | 1610 | 1050 | 455 | 7800*2100*2450 | 1950 |
OSM1500 | 13500 | 6100 | 2300 | 1500 | 650 | 10500*2300*2600 | 2100 |
OSM1800 | 16200 | 7320 | 2760 | 1800 | 780 | 13000*2350*2600 | 2600 |
Design reference :
Compressed air inlet pressure 9 bar(g)/130 psi(g)
Air quality 1.4.1 according to ISO 8573-1:2010
Nitrogen outlet pressure 7 bar(g)/101psi(g)
Nitrogen quality 1.2.1 according to ISO 8573-1:2010.
Designed working temperature max 50 ℃
Dew point at Nitrogen outlet - 50 ℃
Notes:
Compressed air inlet pressure decide membrane performance
Following request of membrane nitrogen generator will be customized :
Compressed air pressure >14 bar(g)/203 psi(g) max up to 24 bar(g)/350 psi(g)
Working pressure >24 bar(g)/350 psi(g)
Dew point < - 50 ℃
Movable/containerized , plug and play
Diesel drive
Other special requirements as per site conditions