Two Stage Nitrogen Purification Unit With Extremely Low Oxygen And Hydrogen
Product Working Principle:
The equipment consists of two parts. The first part is deoxidation and the second part is dehydrogenation. The residual oxygen is removed by deoxidation process. It means the hydrogen reacts with oxygen under the action of catalyst. And then, the hydrogen is removed in the dehydrogenation process.
This unit is suitable for those strict place where only allow extreme low hydrogen and oxygen, the residual oxygen is below 2ppm and hydrogen is below 5ppm after purification.
Technical Indicators:
Nitrogen Purity (Raw Gas) | >98% |
Residual Oxygen % (after purification) | ≤ 2ppm |
Residual Hydrogen % (after purification) | ≤ 5ppm |
Dew Point | ≤ -70 ℃ |
Nitrogen Purity (after purification) | 99.999% |