LCD Display Respirator Mobile Ventilator Machine Trolley type
Introduction
entilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.
Parameters
TECHNIQUES SPECIFICATIONS | |
Physical specifications | |
Display | LED Display |
Mode: | pneumatically powered and electrically controlled system |
Trolley: | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Technical Specifications: | |
Gas requirement: | Medical oxygen with a pressure ranging from 280~600kpa |
safety valve | <12.5 kPa |
Respiratory Rate | 6~60 times/ min |
Oxygen concentration output | <50% |
minute volume | ≥18L |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH |
PEEP: | 0.1 ~ 1.0 kPa |
Ptr: | -4 ~ 10 hPa |
IMV frequency: | 1~12 bpm |
I/E Ratio: | 1:1.5; 1:2.0; 1:2.5; 1:3.0 |
Tidal Volume | Not less than 50~ 1200ml |
Inspiratory Plateau: | 0~1s |
Maximum Safety Pressure | ≤ 6.0kPa |
Sigh: | one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point |
Pressure limit range: | 0 ~ 6.0 kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.9 kPa ~ 5.4 kPa; Upper: 0.5 kPa |
±0.2 kPa | |
Ventilation Volume alarm: | ≥ 18L/ MIN |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. | |
Operating conditions | |
Ambient temperature: | 10 ~ 40oC |
Relative humidity: | no higher than 80 % |
Atmospheric pressure: | 860 hPa ~ 1060 hPa |
Power requirement: | 100-120 Vac, 50/60 Hz; |
Attention: the AC power supply used for the ICU ventilator must be well grounded. | |
Storage | |
Ambient temperature: | -15oC ~ +50oC |
Relative humidity: | no higher than 95 % |
Atmospheric pressure: | 86 kPa ~ 106 kPa. |
It should be stored in a room without corrosive gas and well ventilated | |
Package | |
packaging box | comply with the requirement of GB/T 15464 |
Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation | |
Moisture protection and rain protection to ensure that product is protected from natural damage. | |
Safty & Alarm | |
Gas source pressure | Immediate alarm; “high level alarm” indicator flickers raising an audible alarm. |
Airway Pressure Alarm | The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. |
Tidal Volume Alarm |
Product tags
Lcd Display Respirator Mobile Breathing Machine Used In Hospitals Trolley Type For Icu Room Ask Latest Price
Price :
Negotiation
Color :
White,Orange red yellow blue grey etc.,Grey
Logo :
as you required
Li-battery :
2200mAH
Packaging Details :
Box Or Bag
Payment Terms :
T/T
Contact Supplier
Foshan Nanhai Jinke Consulting Co., Ltd