Specifications
Brand Name :
Huatec
Model Number :
HGM-BZ75
Certification :
ISO CE GOST
Place of Origin :
China
MOQ :
1 set
Payment Terms :
L/C, T/T, Western Union,Paypal
Supply Ability :
500 sets one month
Delivery Time :
3~7 working days
Packaging Details :
Packed in high quality cartons
Product name :
Gloss meter
Model :
HGM-BZ75
Test range :
0.0-300.0(Gs)
Test caliber :
16×48(mm)rectangular
Description

High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing

Standard

International standard ISO-8254, TAPPI - T480, ASTM-C346, ASTM-D2457, DIN67530 and China standard GB8941.3

The technical parameters follows China metrology standard JJG696-2002.

Application
BZ75 ° intelligent glossiness meter is follow ISO - 8254, TAPPI - T480, GB8941.3 standard manufacture high-precision, miniaturization, intelligent paper with glossiness plan, suitable for paper, etc, the paper is printed paper surface gloss surface lens to value measurement.

Parameter

The technical parameters up to JJG 696 (First-level standards).
  1. test range:0.0-300.0(Gs)
  1. test accuracy:<1.2(Gs)
  1. stability:0.4Gs/30min
  1. test caliber:16×48(mm)rectangular
  1. size:128×35×64 (mm)
  1. power:4.8V (Rechargeable battery inside)

Features
1. Small and light, real easy to be carried and used.
2. 4.8V Rechargeable battery can be used for almost 60 hours and 10000 reading.
3. High stability
4. Long-term stable light source needs no replacing forever.
5. Quartz crystal standard board, no excursion.

6. Single-chip microcomputer control circuit, the new keystrokes, light and portable, a single calibration, intelligent calibration record values

Use of equipment

Press the power switch in the measurement mode, apparatus on the sample, the samples showed that the numerical point of view at this time of the gloss value (Gs). When the "angle/ shift" button, switch different angle measurement, the corresponding point of display lights. Whether measured by that point, when measured value greater than 300.0 Gs, shows that "OVER" word.

When the electricity shortage Show "bAtt" words, at this time should be promptly charged with exclusive power rechargeable battery, charging devices plug into the mains socket on the side of charge, charging time in about four hours. Charging standards "⊕", charging the panel led by lit.

Calibration:

When standard equipment on board showed that the standard plate with the corresponding numerical point of difference is greater than the nominal value of 1.2 gloss units at the following methods should be calibrated:

And measuring window on the black velvet board, press the "load switch / zero setting" button, this shows that numerical 0.0.

Black glass plate instead of the standard black velvet boards, measuring instruments on the window, rather than pressing the "calibration / test" button to enter the set, and then display the "000" and the first "0" flashing. Rather than pressing the "angle / shift" key-flashing Move right, rather than pressing the "load switch / zero setting" key "flicker" of numerical change from 0-9-0 through the press "angle / shift" and "load switch / zero setting"key to making shows that numerical standards and black glass plate corresponding nominal value of the same, at this time rather than pressing the" calibration / test "button to complete the setup. And white ceramic standard equipment on board, show that numerical standards-and-white ceramic plate angle of the corresponding nominal value of the error should not exceed ± 1.2 gloss units, it should be considered standard plate dirt, and other issues. Which point of error of work, occupation which should be in work mode in accordance with the perspective of the above process of calibration. After the completion of the steps of the samples can be measured.

Attention

The equipment built four rechargeable batteries,

Standard Delivery

Gloss meter 1pc
Instrument case 1pc
Standard board

2pc

A black board is used for the highlight calibration

A white board is used for the low light calibration

Battery charger 1pc
English instruction manual 1pc
Calibration certificate 1pc

High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing

Send your message to this supplier
Send Now

High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing

Ask Latest Price
Brand Name :
Huatec
Model Number :
HGM-BZ75
Certification :
ISO CE GOST
Place of Origin :
China
MOQ :
1 set
Payment Terms :
L/C, T/T, Western Union,Paypal
Contact Supplier
High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing
High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing
High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing
High Precision 75 Degree Paper Gloss Meter HGM-BZ75 For Paper Testing

HUATEC GROUP CORPORATION

Verified Supplier
10 Years
beijing, beijing
Since 2007
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Seller
Total Annual :
500000-1000000
Employee Number :
35~50
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement