High quality and high performance Various new functions ultrasonic flaw detector FD-600
Performance Features
1.Measurement displaying mode: type A displaying mode
2.It is provided with linear reject function, the highest reject is 80% of the screen height;
3.switch over arbitrarily among three detecting modes: single-probe , dual-probe ones and through transmission;
4.It has gate setting and alarming function. Can set the position and width of gate freely on the screen, and can set alarm for forbidden wave and loss wave respectively;
5.500 detecting channels are available with a separate detecting parameter and DAC curve in every channel.
6.500 A scanned images, parameters and DAC curves can be stored in
7.Two input methods, angles and K value.
8.Auto-gain
11.Automatic generation of AVG curve by three type of flaw
12.Make test videos and Auto playback
13.Auto shutdown mode to save power ;
14.Can playback the saved images, call out the saved A-scan images from
Equipped with delete function, with which any data can be deleted from storage zone;
15. Two measuring unit: mm/inch;
16. Real-time clock;
17.Auto-calibration of probe.
18.Memory of peaks.
19.Can freeze and defreeze waveform and detection parameters;
20. Can lock/unlock the system parameters;
21.Measuring of sound path and analyze of echo times;
22. Can indicate power state in real time;
23. RS232 communication port available;
24. Having buzzer prompt during operation;
25. Compact, light and easy to operate.
Designation | Technical Data |
Range of scanning (mm) | Range of scanning (mm):0~10000 |
D-delay (ms) | D-delay (ms):-20~+3400 |
P-delay (ms) | P-delay:0.0~99.99 Adjusting steps: 0.01 |
MTLVEL(m/s) | MTLVEL:1000~9999 7 fixed levels: 2260,2730,3080,3230,4700,5920,6300 Adjusting steps: 1 |
Working mode | Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe) |
Frequency of repeating transmitting (MHz) | 0.4–20 |
Gain adjustment (dB) | 0~110 Adjusting step: 0.0,0.2,0.5,1,2,6,12 |
Suppress | 0%~80% of screen height, step: 1% |
Vertical linear error | Vertical linear error is not more than 3% |
Horizontal linear error | Not more than 0.2% in the scanning range |
Allowance of detection sensitivity | ≥62 dB |
Dynamic range | ≥32 dB |
Alarm | Three modes, i.e. forbidden wave, loss wave and auto |
Display | Display: high-brightness graphic lattice |
A-Scan display area | A-Scan display freezing and de-freezing A-Scan filling |
Waveform displaying way | full wave |
Detection channel | 10 |
Data save | 500 A-Scan images (including setting of instrument) |
Standard communication interface with PC | RS232 |
Measuring unit | mm/inch |
Battery | Li battery 4×3.6V 5000mAh |
Power adaptor | Input 100V~240V/50Hz~60Hz Output 9V~12VDC/3A~4A |
Working temperature | 0℃~40℃ |
Working humidity | 20%~90% |
Port type | BNC |
Overall dimension (mm) | 210×150×45 |
Weight (kg) | 1.0 |
Standard configuration | Spare parts | |
1. Host 1 2. One straight probe 3. One oblique probe 4. One test block 5. Two probe lines 6. Power adapter 1 7. Two lithium batteries 8. Seat Charging Unit 1 9. SD Storage Card 10. Reader 1 11. 1 manual 12. One copy of certificate, warranty card and packing card | Instrument bags, straps, belts |
Conatact Person: |
Esther Yu Scan here for my name card |
---|---|
Mobile Phone: | 0086-13910983110 |
Whatsapp: | +86 18846112524 |
Skype: | cindydon |
Address : | 7th Floor, Chengyuan Building B, the Mid. Road of Jiancaicheng Haidian Dist.BeiJing,CHINA 100096 |
Worktime : | 9:00-18:00(Beijing time) |
Business Phone: | 86-10-82921131(Working time) 86-13910983110(Nonworking time) |
Fax : | 86-10-82916893 |