5KVA/ 5kw 60A MPPT GEL BATTERY solar panel stand alone system solar power generator home off grid power systems
Off Grid Solar Power Systems are used to collect and store solar energy to be used by household appliances. These systems typically generate from 100 Watts (very small systems) to 5 kilowatts (larger systems, multi-family homes).
Low frequency INVERTER & CONTROLLER 5KW MPPT OFF GRIDE SYSTEM | ||||
NO. | Dscreption | Specification | QTY | |
1 | Low frequency INVERTER & CONTROLLER 5KW MPPT | 48v 60A / 220v | SET | 1 |
2 | LDK 440W 42V BICFACIAL | A GRADE | PCS | 10 |
3 | GEL 12v250ah | 530*268*265 | pc | 8 |
4 | combine box | 4input 1output | 1 | |
Totally | 20 |
Name | QTY | L | W | H | CBM | weight | totally CBM | totally weight |
*Low frequency INVERTER & CONTROLLER 5KW MPPT | 1 | 546 | 392 | 260 | 0.06 | 28.00 | 0.06 | 28.00 |
*GEL 12v250ah | 8 | 530 | 268 | 268 | 0.04 | 68.00 | 0.30 | 544.00 |
LDK 440W 42V BICFACIAL | 10 | 2200 | 35 | 1085 | 0.08 | 24.00 | 0.84 | 240.00 |
combine box | 1 | 0 | 0 | 0 | 0.00 | 0.00 | 0.00 | 0.00 |
TOTALLY: | 1.20 | 812.00 |
Smart Inverter LH series | ||||||||||
Features: Pure sine ware output Optional MPPT/PWM solar charge controller 60A MPPT Efficiency max 98% DC Start & Automatic Self-Diagnostic Function High Efficiency Design & ”Power Saving Mode” to Conserve Energy Auto restart when Ac is recovering Smart battery charger design for optimized battery performance Selectable charging current based on applications AC input/DC input/Solar input optional priority Auto Restart Voltage | ||||||||||
Capacity(VA) | LH1000V | LH1500VA | LH2000VA | LH3000VA | LH4000VA | LH5000VA | LH6000VA | LH7000VA | LH8000VA | LH10000VA |
Rated Power | 800W | 1200W | 1600W | 2400W | 3200W | 4000W | 5000W | 5600W | 6400W | 8000W |
Voltage(DC) | 12V | 24V/48V | 48V | |||||||
Nominal Voltage | 220VAC | |||||||||
Voltage Range | 154-265VAC ;185-264VAC ( selectable) | |||||||||
Frequency | 50-60HZ Auto sensing | |||||||||
Power Factor | 0.8 | |||||||||
Voltage | 220VAC | |||||||||
Frequency | 50/60HZ | |||||||||
Waveform | Pure Sine Wave | |||||||||
Transfer Time (AC to DC) | <8ms | |||||||||
Transfer Time (DC to AC) | <8ms | |||||||||
Output Voltage Regulation | 土10% | |||||||||
Bypass Mode | Yes | |||||||||
Saver Mode | Yes | |||||||||
Efficiency | >98% | |||||||||
Input Protection | Circuit Breaker | |||||||||
Output Protection | Circuit Breaker | |||||||||
Battery Type | VRLA / GEL /GEL DEEP CYCLE | |||||||||
Charging Current | 20A | 30A | 20A/10A | 30A/15A | 40A/20A | 55A/28A | 30A | 40A | 45A | 55A |
Low Level disconnect (Selectable) | 10V- 11V | 20V -22V/40V-44V | 40V -42V | |||||||
PWM controller Voltage range | 15VDC-33VDC | 30VDC-66VDC | 60VDC-150VDC | |||||||
PWM Maximum PV display open circuit voltage | 38V | 75V | 75V | |||||||
Maximum PV array power | 720W | 1400W/2800W | 3400W | |||||||
MPPT control voltage range | 18V-150V | 34V-150V/68V-150V | 60V-150V | |||||||
MPPT Maximum PV display open circuit voltage | 150VDC | |||||||||
Maximum solar charge current | 60A | |||||||||
LCD indicator status | AC input voltage/input frequency, PV voltage, PV current , Output Voltage/Frequency, Battery voltage, Load current etc. | |||||||||
LED indicator status | AC Line In:Green/Inverter:Red/Charging :Yellow/Alarm :Red | |||||||||
LOW battery alarm | Audible alarm-5 seconds beeping | |||||||||
Overload alarm | Audible alarm- continuous beeping | |||||||||
Fault | Audible alarm- continuous beeping | |||||||||
Temperature | 0-60℃ | |||||||||
Humidity | —10℃~90℃ Non condensing | |||||||||
Accoustic Noise(db) | >55dB | |||||||||
Size L*W*H(mm) | 470mm*335mm*210mm | 720mm*335mmm*210mm | ||||||||
Weight (kg) | 12 | 18.5 | 18.5 | 20 | 22 | 22 | 23 | 27 | 30 | 33 |
ELECTRICAL PARAMETERS@STC CM144H-430〜450 | |||||
Max. Power Output Pmax (W) | 430 | 435 | 440 | 445 | 450 |
Power Tolerance | 0-3% | 0 〜+3% | 0-+3% | 0~+3% | 0 〜+3% |
Max. Power Voltage Vmp (V) | 41.27 | 41.47 | 41.67 | 41.87 | 42.06 |
Max. Power Current Imp (A) | 10.42 | 1049 | 10.56 | 10.63 | 10.7 |
Open Circuit Voltage Voc (V) | 49.65 | 49.85 | 50.05 | 50.26 | 50.43 |
Short Circuit Current Isc (A) | ll.O8 | Il.l5 | H.22 | H.29 | H.36 |
Module Efficiency (%) | 19.46 | 19.69 | 19.92 | 20.14 | 20.37 |
STC (Standard Test Condition): Irradiance lOOOW/m2 , Cell Temperature 25OC, Air Mass 1.5 | |||||
ELECTRICAL PARAMETERS@NMOT | |||||
Max. Power Output Pmax (W) | 323 | 327 | 331 | 334 | 338 |
Max. Power Voltage Vmp (V) | 38.45 | 38.64 | 38.82 | 39.01 | 39.19 |
Max. Power Current Imp (A) | 8.4 | 8.46 | 8.52 | 8.57 | 8.63 |
Open Circuit Voltage Voc (V) | 47.19 | 47.38 | 47.57 | 47.77 | 47.93 |
Short Circuit Current Isc (A) | 8.93 | 8.99 | 9.05 | 9.1 | 9.16 |
Nominal Module Operating Temperature (NMOT), Irradiance of 800W/m2, Spectrum AM 1.5, Ambient Temperature 20°C, Wind Speed Im/s | |||||
TEMPERATURE COEFFICIENTS | |||||
Temperature Coefficients of Pmp | -0.36%/°C | ||||
Temperature Coefficients of Voc | -0.29%/°C | ||||
Temperature Coefficients of Isc | +0.048%/°C | ||||
MECHANICAL PARAMETERS | |||||
Cell Type | Mono 166 X83mm | ||||
Number of Cells | I44pcs (2X (6X12)) | ||||
Dimensions (L^W*H) | 2l08Xl048X35mm | ||||
Weight | 25kg | ||||
Frame | Anodized Aluminum | ||||
Junction Box | IP67, 3 bypass diodes | ||||
Cable, Length | 4mm2, 350mm |
Nominal Voltage | 12V | |
Nominal Capacity(10HR) | 250AH | |
Dimension | Length | 522 ±3mm (20.55 inches) |
Width | 268 ±2mm (10.55 inches) | |
Container Height | 220 ±2mm (8.66inches) | |
Total Height (withTerminal) | 225 ±2mm (8.86 inches) | |
Approx Weight | Approx 63.8 kg (140.65lbs) | |
Terminal | T11 | |
Container Material | ABS | |
Rated Capacity | 257.3AH/12.8A | (20hr ,1.80V/cell,25℃/77℉) |
250.0 AH/25.0A | (10hr,1.80V/cell,25℃/77℉) | |
218.7 AH/43.7A | (5hr,1.75V/cell,25℃/77℉) | |
198.7 AH/66.2A | (3hr,1.75V/cell,25℃/77℉) | |
161.5 AH/161.5A | (1hr,1.60V/cell,25℃/77℉) | |
Max. Discharge Current | 2000A (5s) | |
Internal Resistance | Approx 2.0mΩ | |
Operating Temp.Range | Discharge : -30~50℃ (5~122℉) | |
Charge : 0~40℃ (32~104℉) | ||
Aircraft signal Storage : -30~40℃ (5~104℉) | ||
Nominal Operating Temp. Range | 25 ±3℃ (77 ±5℉ ) | |
Cycle Use | Initial Charging Current less than 75.0A.Voltage Communication power supply 14.4V~14.9V at 25℃(77℉)Temp. Coefficient -30mV/℃ | |
Standby Use | No limit on Initial Charging Current Voltage Auto controlsystem 13.5V~13.8V at 25℃(77℉)Temp. Coefficient -20mV/℃ | |
Capacity affectedby Temperature | 40℃ (104 ℉)103% | |
25℃ ( 77 ℉ )100% | ||
0℃ ( 32℉ ) 86% | ||
Self Discharge | GEL series batteries may be stored for up to 9months at 25℃(77℉)and battery should be recharge before use. For higher temperatures the time interval will be shorter. | |
Warranty | |
FULL SETS SYSTEM | 1years |
Solar | 12years products on materials 25years liner power performance |
Inverter | 1year |
GEL battery | 1year |
LI battery | 3years |
GRAPHENE battery | 5years |