96V 100A 10KW Off Grid Solar Inverter System
Off grid solar power system comprises of solar photovoltaic panels which are connected to the inverter. A photovoltaic panel generates energy by its system, which can be used in supply of electrical use to any appliance that are connected to the battery storage.
Low frequency INVERTER 10KW OFF GRIDE SYSTEM | ||||
NO. | Dscreption | Specification | QTY | |
1 | Low frequency INVERTER 12KW | 96v / 220v | SET | 1 |
2 | LDK 440W 42V BICFACIAL | A GRADE | PCS | 21 |
3 | 12v200ah | 530*248*265 | pc | 24 |
4 | combine box | 4input 1output | 1 | |
5 | CONTROLLER 100a | MPPT | 1 | |
Totally | 48 |
Name | QTY | L | W | H | CBM | weight | totally CBM | totally weight |
Low frequency INVERTER 12KW | 1 | 620 | 376 | 850 | 0.20 | 105.00 | 0.20 | 105.00 |
12v200ah | 24 | 530 | 248 | 265 | 0.03 | 60.30 | 0.84 | 1447.20 |
LDK 440W 42V BICFACIAL | 21 | 2200 | 35 | 1085 | 0.08 | 24.00 | 1.75 | 504.00 |
combine box | 1 | 0 | 0 | 0 | 0.00 | 0.00 | 0.00 | 0.00 |
TOTALLY: | 2.79 | 2056.20 |
Model | 10KVA | 15KVA | 20KVA |
Input Power | 220VAC (Standard) | ||
Range of Input Voltage | Model 220V:154-264VAC ± 3V (Normal Mode) 185-264 ± 3V (UPS Model) | ||
Input frequency | 50/60Hz±5% | ||
Output Rated Power | 8000W | 12000W | 16000W |
AC Output Voltage | The output voltage under AC is the same as the input voltage | ||
AC output frequency | The output voltage frequency under AC is the same as the input frequency | ||
Output Voltage under INV Mode | 220VAC±10% | ||
Output frequency under INV mode | 50/60HZ±1% | ||
Output Waveform under INV Mode | Pure Sine Wave | ||
Battery type | External lead acid battery or water battery | ||
Battery voltage | 96VDC / 192VDC | 96VDC / 192VDC | 192VDC |
Battery Charging Voltage | 108DC / 216VDC | 108DC / 216VDC | 216VDC |
Maximum AC Charging Current | 24A / 15A | 35A / 22A | 30A |
Range of Battery Charging Voltage | 154-264VAC±3V | ||
Transfer Time | ≤10ms(UPS mode)/≤20ms (INV mode) | ||
Load peak ratio | (MAX)3:1 | ||
Static power(W) | 120W | 250W | |
Protection function | Input overcurrent air switch protection under AC mode | ||
overload protection, short circuit protection, low voltage protection, (battery reverse connection insurance) under INV mode | |||
Status display | Dot matrix fine screen plus LED display | ||
Through the page key, can view the AC voltage, AC frequency, PV voltage, PV current, output voltage, output frequency, battery voltage, load current and other parameters. | |||
LED display mains, charging status, inverter status, fault status | |||
Audible alarm | Low battery protection-continuous beeping | ||
Low battery protection-1 second beeping | |||
Overload-continuous beeping | |||
Overload less than 130%-1 second beeping and shutdown the output after 30 seconds; Overload more than 150%,shutdown the output after 300ms | |||
Malfunction-continuous beeping | |||
Working temperature | 0℃~40℃ | ||
Storage temperature | —15℃~45℃ | ||
Relative humidity | —10℃~90℃Non condensing | ||
Accoustic Noise(db) | <45dB | ||
Dimension(L*W*H)mm | 570*300*680 | ||
Packing Dimension(L*W*H)mm | 620*376*850 | ||
N.W (KG) | 69 | 89 | 99 |
ELECTRICAL PARAMETERS@STC CM144H-430〜450 | |||||
Max. Power Output Pmax (W) | 430 | 435 | 440 | 445 | 450 |
Power Tolerance | 0-3% | 0 〜+3% | 0-+3% | 0~+3% | 0 〜+3% |
Max. Power Voltage Vmp (V) | 41.27 | 41.47 | 41.67 | 41.87 | 42.06 |
Max. Power Current Imp (A) | 10.42 | 1049 | 10.56 | 10.63 | 10.7 |
Open Circuit Voltage Voc (V) | 49.65 | 49.85 | 50.05 | 50.26 | 50.43 |
Short Circuit Current Isc (A) | ll.O8 | Il.l5 | H.22 | H.29 | H.36 |
Module Efficiency (%) | 19.46 | 19.69 | 19.92 | 20.14 | 20.37 |
STC (Standard Test Condition): Irradiance lOOOW/m2 , Cell Temperature 25OC, Air Mass 1.5 | |||||
ELECTRICAL PARAMETERS@NMOT | |||||
Max. Power Output Pmax (W) | 323 | 327 | 331 | 334 | 338 |
Max. Power Voltage Vmp (V) | 38.45 | 38.64 | 38.82 | 39.01 | 39.19 |
Max. Power Current Imp (A) | 8.4 | 8.46 | 8.52 | 8.57 | 8.63 |
Open Circuit Voltage Voc (V) | 47.19 | 47.38 | 47.57 | 47.77 | 47.93 |
Short Circuit Current Isc (A) | 8.93 | 8.99 | 9.05 | 9.1 | 9.16 |
Nominal Module Operating Temperature (NMOT), Irradiance of 800W/m2, Spectrum AM 1.5, Ambient Temperature 20°C, Wind Speed Im/s | |||||
TEMPERATURE COEFFICIENTS | |||||
Temperature Coefficients of Pmp | -0.36%/°C | ||||
Temperature Coefficients of Voc | -0.29%/°C | ||||
Temperature Coefficients of Isc | +0.048%/°C | ||||
MECHANICAL PARAMETERS | |||||
Cell Type | Mono 166 X83mm | ||||
Number of Cells | I44pcs (2X (6X12)) | ||||
Dimensions (L^W*H) | 2l08Xl048X35mm | ||||
Weight | 25kg | ||||
Frame | Anodized Aluminum | ||||
Junction Box | IP67, 3 bypass diodes | ||||
Cable, Length | 4mm2, 350mm |
Product Paramenters
Nominal Voltage | 12V | |
Nominal Capacity (10HR) | 200AH | |
Dimension | Length | 522 ±3mm (20.55 inches) |
Width | 240 ±2mm (9.45 inches) | |
Container Height | 221 ±2mm (8.70 inches) | |
Total Height (withTerminal) | 226 ±2mm (8.89 inches) | |
Approx Weight | Approx 55.0 kg (121lbs) | |
Terminal | T11 | |
Container Material | ABS | |
Rated Capacity | 209.1 AH/10.4A | (20hr ,1.80V/cell,25℃/77℉) |
200.0 AH/20.0A | (10hr,1.80V/cell,25℃/77℉) | |
173.0 A H/34.6A | (5hr,1.75V/cell,25℃/77℉) | |
157.2 AH/52.4A | (3hr,1.75V/cell,25℃/77℉) | |
122.8 AH/122.8A | (1hr,1.60V/cell,25℃/77℉) | |
Max. Discharge Current | 1800A (5s) | |
Internal Resistance | Approx 3.4mΩ | |
Operating Temp.Range | Discharge : -30~50℃ (5~122℉) | |
Charge : 0~40℃ (32~104℉) | ||
Aircraft signal Storage : -30~40℃ (5~104℉) | ||
Nominal Operating Temp. Range | 25 ±3℃ (77 ±5℉ ) | |
Cycle Use | Initial Charging Current less than 60.0A.Voltage Communication power supply 14.4V~15.0V at 25℃(77℉)Temp. Coefficient -30mV/℃ | |
Standby Use | No limit on Initial Charging Current Voltage Auto controlsystem 13.5V~13.8V at 25℃(77℉)Temp. Coefficient -20mV/℃ | |
Capacity affectedby Temperature | 40℃ (104 ℉)103% | |
25℃ ( 77 ℉ )100% | ||
0℃ ( 32℉ ) 86% | ||
Self Discharge | GEL series batteries may be stored for up to 6 months at 25℃(77℉) and battery should be recharge before use . For higher temperatures the time interval will be shorter. |
Warranty | |
FULL SETS SYSTEM | 1years |
Solar | 12years products on materials 25years liner power performance |
Inverter | 1year |
GEL battery | 1year |
LI battery | 3years |
GRAPHENE battery | 5years |