1t High efficiency environment protection automatic electric heating thermal oil boiler
Electric heating heat transfer furnace system by explosion-proof electric heater, organic heat carrier furnace, heat exchanger (configurable), control cabinet, heat pump, expansion tank and other combination into a pry block, the user only need to plug into the power supply, media import and export pipe steam and some electrical interface can be used. The thermal oil heater (also known as the thermal oil heater) is to directly insert the electric heater into the organic carrier (thermal oil) direct heating, using the circulating pump, forcethe thermal oil to carry out liquid phase circulation, transfer heat to one or more heat ingress, after unloading with heat equipment, re-use the circulating pump, back to the heater, and then absorb heat, pass to the heating equipment, so that the continuous transfer of heat, so that heat is continuously transferred, so that heat is heated. The thermal oil heater uses several temperature control instrument control, with super-temperature alarm, low oil level alarm, super-pressure alarm function, it is chemical, petroleum, machinery, printing and dyeing, food, ships, textiles, filmand and other industries in a high-efficiency and energy-saving heating equipment.
parameters
DRYL-700
NO; | Name | Unit | Number | Description |
1 | Rated thermal power | KW | 700 | |
2 | Rated working power | Mpa | 1.0 | |
3 | Rated inlet/outlet ℃ | ℃ | 310/290 | |
4 | Design efficiency | % | 92.45(Oil) 92.13(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | Be added economizer |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 70.77(Oil) | |
Nm³/h | 86.53(Gas) | Be added economizer | ||
9 | Radiation heating area | m² | 7.199 | |
Convection heating area | m² | 28.71 | ||
GGH heating area | m² | 10.965 | ||
10 | Fume temperature | ℃ | 136.68(Oil) | |
℃ | 137.02 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | Be added economizer |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 0.46 | |
14 | Bulk weight | kg | 4250 | |
15 | Bulk size | mm | 3256×1727×2181 | |
16 | Chimney | mm | Φ325×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
Pre-sale service:
We help customer choose the best boiler model according to
different requirements of various industry. Before delivery we
will provide foundation drawing, layout drawing, boiler room
layout, etc.
In-sale service:
We keep 24 hours online and keep close contacts during the
production process to ensure on time delivery with perfect
finished product.
After-sale service:
1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is
available.
3. Our engineers will held a training for boiler workers to
ensure the safe operation.
4. Free maintenance and repair for one year and lifelong
service.