Non Pollution High Efficiency Installation Simple Electric Heating Thermal Oil Boiler
The environmental protection and flexible use of the thermal oil system makes its biggest bright spot, especially in high temperature training, template heating, rubber, drying, printing and dyeing, chemical and other industries are widely used, in this small compilation suggested that the daily cleaning of the thermal heating oil system can not be sloppy, and the indicators of thermal oil should also be regularly tested, otherwise, such as the impact of production will not be paid. The above is a little superficial understanding of the daily precautions of the thermal oil electric heating system, I hope to help you.
Part of product parameters
YY(Q)W-700Y(Q)
NO; | Name | Unit | Number | Description |
1 | Rated thermal power | KW | 700 | |
2 | Rated working power | Mpa | 1.0 | |
3 | Rated inlet/outlet ℃ | ℃ | 310/290 | |
4 | Design efficiency | % | 92.45(Oil) 92.13(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | Be added economizer |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 70.77(Oil) | |
Nm³/h | 86.53(Gas) | Be added economizer | ||
9 | Radiation heating area | m² | 7.199 | |
Convection heating area | m² | 28.71 | ||
GGH heating area | m² | 10.965 | ||
10 | Fume temperature | ℃ | 136.68(Oil) | |
℃ | 137.02 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | Be added economizer |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 0.46 | |
14 | Bulk weight | kg | 4250 | |
15 | Bulk size | mm | 3256×1727×2181 | |
16 | Chimney | mm | Φ325×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
YY(Q)W-1400Y(Q)
NO; | Name | Unit | Number | Description |
1 | Rated thermal power | KW | 1400 | |
2 | Rated working power | Mpa | 1.0 | |
3 | Rated inlet/outlet ℃ | ℃ | 310/290 | |
4 | Design efficiency | % | 92.33(Oil) 92.03(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | Be added economizer |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 138.93(Oil) | |
Nm³/h | 169.53(Gas) | Be added economizer | ||
9 | Radiation heating area | m² | 13.124 | |
Convection heating area | m² | 71.233 | ||
GGH heating area | m² | 29.845 | ||
10 | Fume temperature | ℃ | 139.26(Oil) | |
℃ | 139.27 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | Be added economizer |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 1.08 | |
14 | Bulk weight | kg | 8389 | |
15 | Bulk size | mm | 4869×2070×2698 | |
16 | Chimney | mm | Φ400×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
Pre-sale service:
We help customer choose the best boiler model according to
different requirements of various industry. Before delivery we
will provide foundation drawing, layout drawing, boiler room
layout, etc.
In-sale service:
We keep 24 hours online and keep close contacts during the
production process to ensure on time delivery with perfect
finished product.
1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is
available.
3. Our engineers will held a training for boiler workers to
ensure the safe operation.
4. Free maintenance and repair for one year and lifelong
service.