High efficiency environment protection automatic electric heating thermal oil boiler
1, electric heating thermal oil furnace as a new type, safe, environmental protection of energy-efficient equipment, its characteristics are high thermal efficiency, strong thermal stability, energy saving, normal pressure operation, safe and reliable, no water resources consumption.
2, electric heating thermal oil furnace structure principle is: electric heating thermal oil furnace through the high temperature oil pump, the heating of the heat transfer oil to the use of heat equipment, after thermal unloading, and then return edgy heating heating tube, using high temperature oil pump will guide the heat oil to circulate, heat transfer to the heat equipment, and then re-circulate the pump, return to the heat heater, absorb heat, and then use the heat transfer to the heat equipment, so repeated heat transfer.
3, electric heating thermal oil furnace is widely used in chemical, paper, textile printing and dyeing, building materials, food, medicine and other industries, in energy conservation and consumption reduction, health production, environmental protection, improve economic and social benefits and other aspects play an important role.
Part of product parameters
DRYL-700
NO; | Name | Unit | Number | Description |
1 | Rated thermal power | KW | 700 | |
2 | Rated working power | Mpa | 1.0 | |
3 | Rated inlet/outlet ℃ | ℃ | 310/290 | |
4 | Design efficiency | % | 92.45(Oil) 92.13(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | Be added economizer |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 70.77(Oil) | |
Nm³/h | 86.53(Gas) | Be added economizer | ||
9 | Radiation heating area | m² | 7.199 | |
Convection heating area | m² | 28.71 | ||
GGH heating area | m² | 10.965 | ||
10 | Fume temperature | ℃ | 136.68(Oil) | |
℃ | 137.02 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | Be added economizer |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 0.46 | |
14 | Bulk weight | kg | 4250 | |
15 | Bulk size | mm | 3256×1727×2181 | |
16 | Chimney | mm | Φ325×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
DRYL-1400
NO; | Name | Unit | Number | Description |
1 | Rated thermal power | KW | 1400 | |
2 | Rated working power | Mpa | 1.0 | |
3 | Rated inlet/outlet ℃ | ℃ | 310/290 | |
4 | Design efficiency | % | 92.33(Oil) 92.03(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | Be added economizer |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 138.93(Oil) | |
Nm³/h | 169.53(Gas) | Be added economizer | ||
9 | Radiation heating area | m² | 13.124 | |
Convection heating area | m² | 71.233 | ||
GGH heating area | m² | 29.845 | ||
10 | Fume temperature | ℃ | 139.26(Oil) | |
℃ | 139.27 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | Be added economizer |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 1.08 | |
14 | Bulk weight | kg | 8389 | |
15 | Bulk size | mm | 4869×2070×2698 | |
16 | Chimney | mm | Φ400×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
Pre-sale service:
We help customer choose the best boiler model according to
different requirements of various industry. Before delivery we
will provide foundation drawing, layout drawing, boiler room
layout, etc.
In-sale service:
We keep 24 hours online and keep close contacts during the
production process to ensure on time delivery with perfect
finished product.
After-sale service:
1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is
available.
3. Our engineers will held a training for boiler workers to
ensure the safe operation.
4. Free maintenance and repair for one year and lifelong
service.