For Brewery Industries Fully Automatic Control System Gas Fired Steam Boiler
The thermal efficiency of the brewing boiler is more than 85%, the combination of the corrugated furnace bile with the cone-shaped furnace bile with the good expansion performance is used, the furnace bile size coincides with the flame, the flue gas circulation area decreases, makes the flue gas flow at such speed, ensures the heat exchange time of high temperature flue gas in the furnace, and achieves the best heat transfer effect.
The special boiler of brewing adopts a high-performance combustion machine which exactly matches the boiler, carries on the full automatic regulation, makes the combustion full, saves fuel and reduces the pollution, uses the ultra-fine glass cotton with high insulation performance, the heat loss is less, the intelligent energy-saving control system, controls the boiler and the supply (water supply) system, combined with different loads to adjust the fuel supply, and more energy-saving.
Product parameters
WNS2-1.25-YQ
NO; | Name | Unit | Number | Description |
1 | Rated evaporation | t/h | 2 | |
2 | Rated working power | Mpa | 1.25 | |
3 | Rated outlet ℃ | ℃ | 193 | |
4 | Design efficiency | % | 92.6(Oil) 92.46(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 137.9(Oil) | |
Nm³/h | 167.325(Gas) | |||
9 | Radiation heating area | m² | 8.527 | |
Convection heating area | m² | 41.838 | ||
GGH heating area | m² | 23.195 | ||
10 | Fume temperature | ℃ | 137.863(Oil) | |
℃ | 134.28 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 5 | |
14 | Bulk weight | kg | 9700 | |
15 | Bulk size | mm | 4531×2150×2544 | |
16 | Chimney | mm | Φ500×10000 | |
17 | Total power consumption | KW | Oil:13,Gas:11 | |
18 | Combustion model | / | Micro positive pressure | Chamber combustion |
19 | Boiler structure feature(Three-pass structure) | Horizontal-type chamber combustion | ||
20 | Control way | Full automation/Manual | ||
21 | Ignition way | High-tension/Electrode |
WNS4-1.25-YQ
NO; | Name | Unit | Number | Description |
1 | Rated evaporation | t/h | 4 | |
2 | Rated working power | Mpa | 1.25 | |
3 | Rated outlet ℃ | ℃ | 194 | |
4 | Design efficiency | % | 92.06(Oil) 92.17(Gas) | |
5 | Boiler heat efficiency | % | More than 98% | |
6 | Design fuels | / | Light oil,Gas | |
7 | Fuels LHV | MJ/kg | 42.917(Oil) | |
MJ/Nm3 | 35.438(Gas) | |||
8 | Consumption of fuels | kg/h | 275.8(Oil) | |
Nm³/h | 334.65(Gas) | |||
9 | Radiation heating area | m² | 10.955 | |
Convection heating area | m² | 83.887 | ||
GGH heating area | m² | 21.488 | ||
10 | Fume temperature | ℃ | 140.6(Oil) | |
℃ | 137.75 (Gas) | |||
11 | Fume temperature | ℃ | 60-80 | |
12 | Excess air coefficient | / | 1.15 | |
13 | Volume | m3 | 5 | |
14 | Bulk weight | kg | 8000 | |
15 | Bulk size | mm | 4300×1900×2400 | |
16 | Chimney | mm | Φ400×10000 | |
17 | Combustion model | / | Micro positive pressure | Chamber combustion |
18 | Boiler structure feature(Three-pass structure) | Horizontal-type chamber combustion | ||
19 | Control way | Full automation/Manual | ||
20 | Ignition way | High-tension/Electrode |
Our services
Pre-sale service:
We help customer choose the best boiler model according to
different requirements of various industry. Before delivery we
will provide foundation drawing, layout drawing, boiler room
layout, etc.
In-sale service:
We keep 24 hours online and keep close contacts during the
production process to ensure on time delivery with perfect
finished product.
After-sale service:
1. provide full range of original spare parts.
2. Engineers abroad installation and commissioning service is
available.
3. Our engineers will held a training for boiler workers to
ensure the safe operation.
4. Free maintenance and repair for one year and lifelong
service.